Rapid ornithine decarboxylase test for the identification of enterobacteriaceae.
نویسندگان
چکیده
Conventional methods for detecting ornithine decarboxylase activity require an extended period of incubation. However, with a few simple modifications, accurate results were obtained within a few hours rather than several days. The broth medium was modified, primarily by omitting glucose and by decreasing the pH to 5.5. A 1-ml amount of this broth was inoculated with one colony and then overlaid with sterile mineral oil. Within 2 to 4 hr, the pH increased if ornithine was decarboxylated, thus changing the color of the internal pH indicator to a dark purple. If the amino acid was not decarboxylated, the pH decreased to pH 5.0 to 5.2, enough to give a definite yellow color. With 347 selected clinical isolates, the rapid test gave results identical to those obtained in 1 to 4 days with Moeller's decarboxylase medium. Less reliable results were obtained with Difco's decarboxylase medium with 0.3% agar which was stabinoculated and read after 18 to 24 hr without a mineral oil seal. The rapid ornithine decarboxylase test represents a simple, accurate technique which is well suited for the clinical microbiology laboratory.
منابع مشابه
Evaluation of the pathotec Rapid I-D system for identification of Enterobacteriaceae.
The PathoTec Rapid I-D System for identifying Enterobacteriaceae was evaluated with 471 cultures. In 4,910 individual test comparisons, 95.5% of the results agreed, with results of only two test strips, those for esculin hydrolysis and urease production, agreeing with conventional tests in less than 94% of the trials. The PathoTec system exhibited 94.3% accuracy in identifying these cultures in...
متن کاملA rapid method for determining decarboxylase and dihydrolase activity.
A total of 764 fresh clinical isolates were used to test a rapid method for determining lysine, arginine, and ornithine decarboxylase activity as well as arginine dihydrolase activity. The conventional Møller decarboxylase broth was tested in parallel with the rapid method on 234 Enterobacteriaceae and 140 non-fermentative Gram-negative rods. The 0.3% agar method was tested in parallel on 245 E...
متن کاملEvaluation of modified R-B system for identification of members of the family Enterobacteriaceae.
In a paired, double-blind study, the modified ("Beckford tube") R-B system was compared with conventional bacteriological procedures for the identification of members of the family Enterobacteriaceae from clinical isolates and stock cultures. The tests in the R-B system yielding positive reactions comparable to those predicted by Ewing's taxonomic classification of Enterobacteriaceae were produ...
متن کاملRapid identification of Enterobacteriaceae with the micro-ID system versus API 20E and conventional media.
The Micro-ID system for rapid (4 h) identification of Enterobacteriaceae was evaluated by testing 433 enteric bacilli and 9 other gram-negative bacilli. Each isolate was identified with conventional tubed media and was also tested in the Micro-ID and API 20E systems. The overall accuracy of both systems was 97%. Micro-ID tests for the Voges-Proskauer reaction, indole and H2S production, and orn...
متن کاملEvaluation of accuracy of multitest micromethod system for identification of Enterobacteriaceae.
The Analytab system of 20 biochemical tests for identification of Enterobacteriaceae was evaluated in parallel with conventional tests on 128 Enterobacteriaceae, 5 Aeromonas, and 1 Yersinia enterocolitica. The results of tests for H(2)S and indole production, citrate utilization, lysine and ornithine decarboxylase, arginine dihydrolase, nitrate reduction, beta-galactosidase, and fermentation of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied microbiology
دوره 23 4 شماره
صفحات -
تاریخ انتشار 1972