The Improvement of Motor Cooling Through Stator Profile Optimization using CFD Analysis in Hermetic Scroll Compressors
نویسندگان
چکیده
Hermetic compressor motor design face the challenge today that reducing the motor size for cost reason. This causes a higher motor power density and in turns a higher motor temperature. With the help of CFD computation tool, we investigated two ways to improve the motor cooling and bring the motor temperature down. One way is to put rotor ventilation channels to increase the flow in lower pressure side, so that the total percentage of suction gas to cool the motor increased. The other way is to optimize the stator cuts depending on flow rate in each stator cut. By combining these two improvement together, total motor temperature, particularly in stator end wing and rotor lower end ring, was reduced dramatically. Both motor and compressor prototype were tested and results given.
منابع مشابه
Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load
An experimental rig has been built to test a horizontal scroll compressor and a reciprocating compressor of similar size and capacity. The compressors were tested with refrigerant.R404A operating at varying evaporator and condenser temperatures. The paper provides much needed information regarding the efficiency of the compressors operating under the same conditions with the same system paramet...
متن کاملA Hermetic Scroll Compressor For Application To High Heat Of Compression Gases
A horizontal hermetic scroll compressor has been developed for applications with high heatof-compression gases, including natural gas, air and helium (cryogenics). The compressor is a low profile horizontal design with oil-flooded cooling of the compression process. Combined with components required for oil separation and cooling, this design provides a smooth, continuous compression process fe...
متن کاملNumerical Study and Experimental Comparison of CO2 Reciprocating Compressors for Small Cooling and/or Freezing Capacity Applications
The present paper is a numerical and experimental comparative study of hermetic and semi-hermetic reciprocating compressors working with carbon dioxide as fluid refrigerant against the conventional R134a hermetic compressors. When cooling conditions for one-stage compressor type (i.e., evaporation temperatures between 7.2oC and –10oC) have been considered, the numerical and experimental results...
متن کاملCFD Studies of Flow in Screw and Scroll Compressors
An analysis of flow in rotary positive displacement machines has been carried out using a standard CFD package by separating out the motions of the fluid and the instantaneous volume in which it is contained. Examples are given of both twin screw and scroll compressors. Pressure-volume diagrams obtained from such analyses are compared with experimental results and good agreement shown. Longer t...
متن کاملA New Switched Reluctance Motor Design to Reduce Torque Ripple using Finite Element Fuzzy Optimization
This paper presents a new design to reduce torque ripple in Switched Reluctance Motors (SRM). Although SRM possesses many advantages in terms of motor structure, it suffers from large torque ripple that causes problems such as vibration and acoustic noise. The paper describes new rotor and stator pole shapes with a non-uniform air gap profile to reduce torque ripple while retaining its average ...
متن کامل