Automated optical counting of blood platelets.

نویسندگان

  • G M Brittin
  • S A Dew
  • E K Fewell
چکیده

We have evaluated the use of an optical particle counter to perform automated platelet counts on whole blood. The erythrocytes were lysed by dilution of whole blood with 2 M urea and the remainmg platelets and leukocytes were enumerated by a darkfield microscope optical system that detects light diffracted by them. A suspension of fixed human platelets available commercially was highly satisfactory for standardization. The method gave accurate and reproducible platelet counts, comparable with those of electronic particle counting on venous blood and substantially more reliable platelet counts on thrombocytopenic and finger-puncture blood samples. We believe that errors resulting from the electronic method were caused by technical difficulties of sample handling and not to an intrinsic error in electronic counting. By using the automated optical method we found no significant difference between the platelet counts of capillary and venous blood, although capillary platelet counts had twice the variability of venous counts. The optical technique has important advantages over electronic platelet counting, and its superiority appears to be due to the ability to count platelets in diluted whole blood rather than in plasma. It should prove especially useful in performing the large numbers of platelet counts on thrombocytopenic and finger-puncture blood samples that are increasingly important for management of patients receiving chemotherapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of mouse red blood cell and platelet counting with an automated hematology analyzer

An evaluation of mouse red blood cell (RBC) and platelet (PLT) counting with an automated hematology analyzer was performed with three strains of mice, C57BL/6 (B6), BALB/c (BALB) and DBA/2 (D2). There were no significant differences in RBC and PLT counts between manual and automated optical methods in any of the samples, except for D2 mice. For D2, RBC counts obtained using the manual method w...

متن کامل

Comparison of platelet counting technologies in equine platelet concentrates.

OBJECTIVE (1) To compare the performance of 4 platelet counting technologies in equine platelet concentrates and (2) to evaluate the ability of the Magellan platelet rich plasma (PRP) system to concentrate equine platelets. STUDY DESIGN Experimental study to assess method agreement. ANIMALS Adult mixed breed horses (n = 32). METHODS Acid citrate dextrose-A anti-coagulated whole blood was ...

متن کامل

[A new automated haematology analyser: the Excell 2280].

Excell 2280 analyser is a new automated haematology analyser manufactured by Drew Scientific Inc, Texas, USA, and distributed in France by MAXMAT S.A., Montpellier. It can achieve 80 complete blood cell counts per hour, with leukocyte differential counts. Three sampling possibilities are included: a direct one (open tubes, 180 microL), a blood saver one (80 microL) and an automatic, through-the...

متن کامل

Enhanced accuracy of optical platelet counts in microcytic anemia.

OBJECTIVE To determine whether microcytic erythrocytes influence the accuracy of automated platelet (PLT) counting. METHODS We divided a total of 206 K2 ethylenediaminetetraacetic acid (EDTA)-anticoagulated blood samples into 4 groups, as follows: In group 1 (control group), normal mean corpuscular volume (MCV > 80 fL) and PLT count equal or greater than 140,000/microL (n = 45); group 2, norm...

متن کامل

Producing accurate platelet counts for platelet rich plasma: validation of a hematology analyzer and preparation techniques for counting.

Platelet rich plasma (PRP) has been shown to clinically accelerate healing of both soft and hard tissues. As a result, it has gained increasing popularity. However, the clinical effectiveness of each type of PRP preparation method can vary in technique and efficiency, and current methods to evaluate the platelet concentration efficiency of PRP systems have several limitations. Therefore, the pu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood

دوره 38 4  شماره 

صفحات  -

تاریخ انتشار 1971