Evaluationof the Bromcresol Purplemethodfor Albuminas Used with the Aca

نویسندگان

  • Richard J. Cooke
  • Robert L Jensen
  • Barry Levine
  • Robert Blanke
  • James Valentour
چکیده

Lidocaine is a frequently administered anti-arrhythmic drug, particularly useful in emergency situations because of its rapid onset of action (1). Therapeutic drug monitoring of lidocaine is recommended because of its potent central nervous system toxicity. Moreover, lidocaine has been implicated in numerous accidental and homicidal deaths (2). Thus its chemical stability in patients’ specimens and in quality-control specimens needs to be known. Two metabolites of lidocaine, monoethylglicinexylidide and glycinexylidide, are unstable in plasma and urine (3), but no work has been published on the stability of lidocaine itself. Therefore, we have assessed the stability of lidocaine in serum and blood. Sera from patients being treated with lidocaine were pooled and stored at -20 #{176}C until used. Cadaver blood containing lidocaine was also collected and pooled. After an initial quantification by gas chromatography (4), the serum and blood were each divided into two portions.One was stored at 25 #{176}C, the other at 4#{176}C. At various time intervals, aliquots of fluid stored ateach temperature were removed and re-assayed. After 70 days, at least 80% of the lidocaine was detected in serum at either temperature. Furthermore, no changes in blood lidocaine concentration were detected over a similar time period at either temperature. Any changes in lidocaine concentration were within the out-of-run CV of the method. We conclude that lidocaine is quite stable in serum and blood over a twoto three-month period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of results from the Du Pont "ACA" and Technicon "SMA 12-60".

The Du Pont “Automatic Clinical Analyzer” (ACA) and the Technicon “SMA 12/60” were compared as to precision, range of linearity, and results for sera from patients. Precision of the ACA was equal to or better than that of the SMA 12/60 for all determinations except SGOT in the normal range. The ACA showed a wider range of linearity for BUN, total protein, LDH, alkaline phosphatase, SGOT, and bi...

متن کامل

Evaluationof the Du Pont aca a - Amylase Procedure

The procedure used with the Du Pont aca for a-amylase (1,4,-a-o-glucan glucanohydrolase, EC 3.2.1.1) was evaluated In our laboratory and compared with the Roche Diagnostics “Amylochrome” and Perkin-Eimer Coleman 91 amylase assays. The within-run coefficients of varIation (CV) for samples of fresh normal sera were: aca 5.8% and 4.3% on two different lots of reagent, Amylochrome 7.4%, and Coleman...

متن کامل

The introduction of bromocresol purple for the determination of serum albumin on SMAC and ACA, and the standardization procedure.

The bromocresol purple methods for the determination of serum albumin on the Technicon SMAC and the DuPont ACA systems were evaluated and compared with the corresponding bromocresol green methods, a radial immunodiffusion (RID) and an electrophoresis technique. The linearity and precision of the dye binding methods were comparable. The bromocresol purple methods were more influenced by lipaemia...

متن کامل

Prevention under the Affordable Care Act (ACA): Has the ACA Overpromised and under Delivered?; Comment on “Interrelation of Preventive Care Benefits and Shared Costs under the Affordable Care Act (ACA)”

This policy brief discusses preventive care benefits and cost-sharing included in health insurance provisions of the Affordable Care Act (ACA) legislation and highlights some consequences to Americans and the country in terms of healthcare costs and value.

متن کامل

Improvement of anticomplementary activity assay for the quality control of immunoglobulin product: an Iranian pilot scale study

Abstract Background and Objectives One of the side effects of immunoglobulin administration is the activation of the complement system related to the high concentration of aggregates/large polymers in the production process. Measuring anticomplementary activity (ACA) is important in pharmaceutical quality control and is a criterion of spontaneous activation of complement system in immunoglobuli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004