Scintillation and detection characteristics of high-sensitivity CeBr3 gamma-ray spectrometers
نویسندگان
چکیده
Crystal growth and detector fabrication technologies have reached such a state of maturity that high-quality large-volume CeBr3 scintillators can now be produced with dimensions of 2′′×2′′ and well above. We present a study of CeBr3 samples of various dimensions and show that they have a number of advantages over equivalently sized LaBr3:5%Ce for gamma-ray spectroscopy applications requiring high detection sensitivity. At the present time, the achieved energy resolution of CeBr3 is about 4% FWHM at 662 keV, i.e. 25% worse than that of LaBr3:5%Ce. However, thanks to the drastically reduced intrinsic activity, CeBr3 gamma-ray detection sensitivity is about 1 order of magnitude better than that of LaBr3:5%Ce at energies of 1461 keV and 2614.5 keV, which are relevant for the detection of 40 K and 208 Tl ( 232 Th), respectively. In this communication, we report on several aspects of CeBr3 gamma-ray spectrometers, such as scintillation characteristics, non-proportionality of the response, gamma-ray detection performances up to 3 MeV and radiation tolerance.
منابع مشابه
CeBr3 Scintillator Development for Possible Use in Space Missions
CeBr3 crystals have been studied to assess their utility as potential gamma ray spectrometers for future ESA planetary missions. Pulse height spectra, scintillation time profiles, X-ray excited emission spectra, and photoluminescence spectra have been recorded as a function of temperature between 78 and 600 K. In addition, the influence of exposing CeBr3 to various doses of gamma rays from a st...
متن کاملGrowth of CsI(Tl) crystals doped with Ca and Tm and investigation of its scintillation characteristics
In this work, the growth of CsI(Tl) crystals as gamma detector was performed using vertical Bridgman method with Ca and Tm co-dopants. For evaluation of the growth crystals, X-Ray Diffraction (XRD), photoluminescence and thermoluminescence spectra as well as recorded gamma spectra were employed. In addition, the scintillation properties including energy resolution, scintillation decay time, abs...
متن کاملComparison between Amperometric and Chemiluminescence methods in detection and dosimetry of cobalt-60 gamma ray emission
Background: Hydrogen peroxide (H2O2), produced by gamma ray irradiation to watery solution, was used as an analytical parameter for dosimetry of cobalt-60 (60Co) radiation. Materials and Methods: Detection of the produced H2O2 was carried out using two methods: an amperometric biosensor fabricated by immobilization of anthraquinone 2-carboxylic acid modified horseradish peroxidase on glassy car...
متن کاملThe Oriented Scintillation Spectrometer Experiment Instrument Description
The Oriented Scintillation Spectrometer Experiment (OSSE) on the Arthur Holly ComptonGammaRay Observatory satellite uses four actively-shielded NaI(Tl)-CsI(Na) phoswich detectors to provide gamma-ray line and continuum detection capability in the 0:05 10 MeV energy range. The instrument includes secondary capabilities for gamma-ray and neutron detection between 10 and 250 MeV. The detectors hav...
متن کاملThe Oriented Scintillation Spectrometer Experiment Instrument Description the Oriented Scintillation Spectrometer Experiment Instrument Description
The Oriented Scintillation Spectrometer Experiment (OSSE) on the Arthur Holly Compton Gamma Ray Observatory satellite uses four actively-shielded NaI(Tl)-CsI(Na) phoswich detectors to provide gamma-ray line and continuum detection capability in the 0:05 ? 10 MeV energy range. The instrument includes secondary capabilities for gamma-ray and neutron detection between 10 and 250 MeV. The detectors...
متن کامل