Non-destructive evaluation of polymer coating structures on pharmaceutical pellets using full-field optical coherence tomography.

نویسندگان

  • Chen Li
  • J Axel Zeitler
  • Yue Dong
  • Yao-Chun Shen
چکیده

Full-field optical coherence tomography (FF-OCT) using a conventional light-emitting diode and a complementary metal-oxide semiconductor camera has been developed for characterising coatings on small pellet samples. A set of en-face images covering an area of 700 × 700 μm(2) was taken over a depth range of 166 μm. The three-dimensional structural information, such as the coating thickness and uniformity, was subsequently obtained by analysis of the recorded en-face images. Drug-loaded pharmaceutical sustained-release pellets with two coating layers and of a sub-millimetre diameter were studied to demonstrate the usefulness of the developed system. We have shown that both coatings can be clearly resolved and the thickness was determined to be 40 and 50 μm for the outer and inner coating layers, respectively. It was also found that the outer coating layer is relatively uniform, whereas the inner coating layer has many particle-like features. X-ray computed microtomography measurements carried out on the same pellet sample confirmed all these findings. The presented FF-OCT approach is inexpensive and has better spatial resolution compared with other non-destructive analysis techniques such as terahertz pulsed imaging, and is thus considered advantageous for the quantitative analysis of thin coatings on small pellet samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantifying Pharmaceutical Film Coating with Optical Coherence Tomography and Terahertz Pulsed Imaging: An Evaluation

Spectral domain optical coherence tomography (OCT) has recently attracted a lot of interest in the pharmaceutical industry as a fast and non-destructive modality for quantification of thin film coatings that cannot easily be resolved with other techniques. Because of the relative infancy of this technique, much of the research to date has focused on developing the in-line measurement technique ...

متن کامل

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases.  Furtherm...

متن کامل

Non-destructive Inspection of Anti-corrosion Protective Coatings Using Optical Coherent Tomography

Optical Coherence Tomography (OCT) is one of the most rapidly advancing techniques. This method is capable of non-contact and non-destructive investigation of the inner structure of a broad range of materials. Compared with other methods which belong to the NDE/NDT group (Non-Destructive Evaluation/Non-Destructive Testing methods), OCT is capable of a broad range of scattering material structur...

متن کامل

Advanced Optical Coherence Tomography techniques: novel and fast imaging tools for NDT

We demonstrate that Optical Coherence Tomography (OCT), a method which was originally developed for depth-resolved imaging of biological tissue, is suited to adequately respond to different problems posed in the field of contactless material characterisation and non-destructive testing and evaluation. In detail, the potential of advanced OCT techniques like ultrahigh-resolution OCT, polarisatio...

متن کامل

Characterization and Evaluation of Novel Film Forming Polymer for Drug Delivery

In this study, Damar Batu (DB) − a novel biomaterial− is evaluated for its potential application in pharmaceutical coating. DB is a whitish to yellowish resin, characterized initially in terms of solubility, acid value, molecular weight (Mw), polydispersity index (Mw/Mn) and glass transition temperature (Tg). Neat plasticized films of DB are investigated for mechanical, water vapor transmission...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pharmaceutical sciences

دوره 103 1  شماره 

صفحات  -

تاریخ انتشار 2014