Proficiency testing of creatine kinase and creatine kinase-2: the experience of the Ontario Laboratory Proficiency Testing Program.

نویسندگان

  • A R Henderson
  • S Krishnan
  • S Webb
  • C M Cheung
  • D J Nazir
  • H Richardson
چکیده

The Ontario Laboratory Proficiency Testing Program has regularly monitored the analytical performance of total creatine kinase (CK) (approximately 230 participants) and CK isoenzyme-2 (CK-MB) (approximately 160 participants) throughout the entire province. Consistently, a wide dispersion of results has been observed not only between different analyzer systems but also among identical analyzers. Accordingly, the results of the last three proficiency surveys for these analytes were examined statistically to establish both the extent of these variations and the range of values reported for the male upper reference ranges. The results of many of the analyzer systems were significantly different from each other, as were many of the reference ranges. This unsatisfactory situation may only be remedied by the use of reference materials as shown by others. The consequences of these findings also effect the reliability of epidemiological surveys such as the WHO MONICA Project (Circulation 1994;90:583-612), which monitors deaths due to heart disease and includes cardiac enzyme results in its criteria.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is determination of creatine kinase-2 after electrophoretic separation accurate?

Since 1991, the Ontario Laboratory Proficiency Testing Program has assessed the analytical performance of creatine kinase (CK; EC 2.7.3.2) isoenzyme-2, using fresh human serum supplemented with purified human CK isoenzymes. In Ontario, the 142 laboratories licensed to analyze CK-2 use a variety of methods: electrophoresis-based, immunoinhibition, and mass assays. During a 1992 survey, duplicate...

متن کامل

Proficiency testing for creatine kinase isoenzyme CK-2 (CK-MB) in Ontario.

Three surveys of the measurement and interpretation of creatine kinase (CK; EC 2.7.3.2) isoenzyme 2 (CK-MB) were conducted in Ontario, Canada, in 1989. Of the clinical laboratories participating, 66% used immunological methods and 24% used electrophoretic methods. Although reference ranges and interpretative routines varied widely, 95% of the laboratories reported correct interpretations for 10...

متن کامل

The Interventional Effect of Dry Cupping Therapy and Creatine Supplementation on Lactic Acid, Lactate Dehydrogenase and Creatine Kinase in Plasma Following Wingate Anaerobic Test in Male Handball Players

Introduction: Optimum recovery can prevent the athlete's functional capacity from falling between training sessions or competitions. The aim of this study was to evaluate the effect of dry cupping therapy and creatine supplementation on lactic acid, lactate dehydrogenase and plasma creatine kinase following the Wingate anaerobic test in male handball players. Method: In this quasi-experimental...

متن کامل

In Vitro Inhibition of Human Sperm Creatine Kinase by Nicotine, Cotinine and Cadmium, as a Mechanism in Smoker Men Infertility

Background Nicotine, cotinine and cadmium are harmful components of cigarettes that have an effect on human reproductive function. Although the effects of cigarette smoke on male reproductive function is characterized in several articles its mechanism of action is still unknown. In the present study, we investigate the effect of nicotine, cotinine and cadmium on human sperm creatine kinase acti...

متن کامل

European specifications for imprecision and inaccuracy compared with operating specifications that assure the quality required by US CLIA proficiency-testing criteria.

Proposed and interim European quality specifications for imprecision and inaccuracy have been compared with the US CLIA total error criteria for proficiency testing (PT). To assess the relative demands of separate imprecision and inaccuracy specifications vs total error criteria, we derived the imprecision and inaccuracy that would be allowable if a testing process were to provide 90% assurance...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 44 1  شماره 

صفحات  -

تاریخ انتشار 1998