Microfluidic polymer chip integrated with an ISFET detector for cationic surfactant assay in dental rinses.

نویسندگان

  • Takashi Masadome
  • Kensuke Yada
  • Shin-ichi Wakida
چکیده

A cationic surfactant ion-selective field-effect transistor (cationic surfactant-ISFET) has been developed based on the tetraphenylborate derivative known as sodium tetrakis[3,5-bis(trifluoromethyl)phenyl]borate. The cationic surfactant-ISFET shows an almost Nernstian response to tetradecyldimethylbenzylammonium chloride (Zephiramine) over a concentration range between 1.0 x 10(-6) M and 1.0 x 10(-3) M, with a slope of 58.5 +/- 1.7 mV/decade. The cationic surfactant-ISFET can be used over a range of pH values, between pH 3 and 9. The cationic surfactant-ISFET shows excellent selectivity for Zephiramine over small inorganic cations, but shows similar selectivity for other cationic surfactants, such as hexadecyltrimethylammonium and stearyltrimethylammonium ions. A microfluidic polymer chip was integrated with the cationic surfactant-ISFET, and this was fabricated using polystyrene plates and stainless wires as a template for the channel. Cationic surfactant-ISFETs used in a batch system and microchips integrated with cationic surfactant-ISFETs showed very similar performance in terms of low detection limits, slope sensitivity and the stability of the potential response. The microfluidic polymer chip was then applied to the determination of cationic surfactants in dental rinses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imaging based optofluidic air flow meter with polymer interferometers defined by soft lithography.

We present an optofluidic chip with integrated polymer interferometers for measuring both the microfluidic air pressure and flow rate. The chip contains a microfluidic circuit and optical cavities on a polymer which was defined by soft lithography. The pressure can be read out by imaging the interference patterns of the cavities. The air flow rate was then calculated from the differential press...

متن کامل

Microfluidic-packaged CMOS chemiresistor detector for micro-scale gas chromatograph

The implementation of a microfluidic ‘detector cell’ is presented, which integrates a nanofabricated chemiresistor (CR) array with monolithic CMOS baseline cancellation circuitry and a microfluidic chamber for use in a micro-scale gas chromatograph (mGC). A robust packaging method was developed to facilitate a microfluidic interface between the detector cell and external mGC components while al...

متن کامل

On-chip cavity-enhanced absorption spectroscopy using a white light-emitting diode and polymer mirrors.

We have developed a disposable microfluidic chip with integrated cavity mirrors comprised of two pieces of 3M Vikuiti™ enhanced specular reflector II (ESRII) film, for performing cavity-enhanced absorption spectroscopy with a white light-emitting diode (LED). Compared to measurements made with a chip without cavity mirrors, the absorption path length is enhanced by a maximum factor of 28 at 544...

متن کامل

Development and Application of Integrated Silicon-in-plastic Microfabrication in Polymer Microfluidic Systems

Title of Document: DEVELOPMENT AND APPLICATION OF INTEGRATED SILICON-IN-PLASTIC MICROFABRICATION IN POLYMER MICROFLUIDIC SYSTEMS Likun Zhu, Doctor of Philosophy, 2006 Directed By: Associate Professor Don L. DeVoe, Department of Mechanical Engineering Polymer-based microfluidic devices can offer a number of advantages over conventional devices, and have found many applications in chemical and bi...

متن کامل

An All-Glass Microfluidic Network with Integrated Amorphous Silicon Photosensors for on-Chip Monitoring of Enzymatic Biochemical Assay

A lab-on-chip system, integrating an all-glass microfluidics and on-chip optical detection, was developed and tested. The microfluidic network is etched in a glass substrate, which is then sealed with a glass cover by direct bonding. Thin film amorphous silicon photosensors have been fabricated on the sealed microfluidic substrate preventing the contamination of the micro-channels. The microflu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 22 8  شماره 

صفحات  -

تاریخ انتشار 2006