Electromagnetic-field distribution measurements in the soft x-ray range: full characterization of a soft x-ray laser beam.

نویسندگان

  • S Le Pape
  • Ph Zeitoun
  • M Idir
  • P Dhez
  • J J Rocca
  • M François
چکیده

We report direct measurement of the electromagnetic-field spatial distribution in a neonlike Ar capillary discharge-driven soft x-ray laser beam. The wave front was fully characterized in a single shot using a Shack-Hartmann diffractive optics sensor. The wave front was observed to be dependent on the discharge pressure and capillary length, as a result of beam refraction variations in the capillary plasma. The results predict approximately 70% of the laser beam energy can be focused into an area 4 times the size of the diffraction-limited spot, reaching intensities of approximately 4 x 10(13) W/cm(2).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-dimensional near-field and far-field imaging of a Ne-like Ar capillary discharge table-top soft-x-ray laser

We have performed systematic measurements and numerical modeling of the divergence and exit beam size of a 46.9 nm Ne-like Ar capillary discharge pumped soft-x-ray amplifier. Two-dimensional near-field and far-field measurements were obtained over a wide range of discharge parameters. The spot size and divergence of the laser beam were observed to increase significantly with decreasing discharg...

متن کامل

Optimum driving a Z-pinch for soft X-Ray lasers

A capillary plasma z-pinch as an alternative active medium of soft X-Ray lasers was studied experimentally and theoretically. The theoretical analysis was based on the self consistent solution of the so called “snow plow” model. The dynamics of pinched plasma is determined by the capillary parameters and by the time dependence of electrical current passing through it. The current time dependenc...

متن کامل

مکانیسم تولید و ویژگی‌های تابش چرنکوف در ناحیه اشعه ایکس نرم

In this paper, the production mechanisms and the spectral-angular distribution of X-ray Cherenkov radiation (XCR) was investigated in detail and some unique properties of XCR and its applications were discussed. It is shown that, in the vicinity of the atomic absorption edges, the real and the imaginary parts of the refractive index are varied drastically and for some materials the refractive i...

متن کامل

استفاده از شتابگر الکترونی MeV 10 برای تولید تابش چرنکوف درناحیه پرتوایکس نرم

Cherenkov radiation is generated when relativistic charged particles move in a medium with refractive index larger than unity. Although, the refractive index is generally smaller than unity in X-ray region, in the vicinity of atomic absorption edges, the refractive index may exceed unity and Cherenkov radiation can be generated in soft X-ray region with a narrow band width. In this paper, the s...

متن کامل

Lateral Soft Tissue X-ray for Patients with Suspected Fishbone in Oropharynx, A thing in the past

Introduction: Fishbone is the most common foreign body found in the oropharynx. Conventionally patients with suspected fishbone in the throat would have mirror laryngoscopy followed by lateral soft tissue X-ray to look for the fishbone or observe impacts caused by the fishbone i.e. soft tissue swelling or air in upper esophagus. However, the most common site of fishbone impact is the suprahyoid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review letters

دوره 88 18  شماره 

صفحات  -

تاریخ انتشار 2002