Prospective randomized study to assess the efficacy of site and rate of atrial pacing on long-term progression of atrial fibrillation in sick sinus syndrome: Septal Pacing for Atrial Fibrillation Suppression Evaluation (SAFE) Study.

نویسندگان

  • Chu-Pak Lau
  • Ngarmukos Tachapong
  • Chun-Chieh Wang
  • Jing-Feng Wang
  • Haruhiko Abe
  • Chi-Woon Kong
  • Reginald Liew
  • Dong-Gu Shin
  • Luigi Padeletti
  • You-Ho Kim
  • Razali Omar
  • Kreingkrai Jirarojanakorn
  • Yoon-Nyun Kim
  • Mien-Cheng Chen
  • Charn Sriratanasathavorn
  • Muhammad Munawar
  • Ruth Kam
  • Jan-Yow Chen
  • Yong-Keun Cho
  • Yi-Gang Li
  • Shu-Lin Wu
  • Christophe Bailleul
  • Hung-Fat Tse
چکیده

BACKGROUND Atrial-based pacing is associated with lower risk of atrial fibrillation (AF) in sick sinus syndrome compared with ventricular pacing; nevertheless, the impact of site and rate of atrial pacing on progression of AF remains unclear. We evaluated whether long-term atrial pacing at the right atrial (RA) appendage versus the low RA septum with (ON) or without (OFF) a continuous atrial overdrive pacing algorithm can prevent the development of persistent AF. METHODS AND RESULTS We randomized 385 patients with paroxysmal AF and sick sinus syndrome in whom a pacemaker was indicated to pacing at RA appendage ON (n=98), RA appendage OFF (n=99), RA septum ON (n=92), or RA septum OFF (n=96). The primary outcome was the occurrence of persistent AF (AF documented at least 7 days apart or need for cardioversion). Demographic data were homogeneous across both pacing site (RA appendage/RA septum) and atrial overdrive pacing (ON/OFF). After a mean follow-up of 3.1 years, persistent AF occurred in 99 patients (25.8%; annual rate of persistent AF, 8.3%). Alternative site pacing at the RA septum versus conventional RA appendage (hazard ratio=1.18; 95% confidence interval, 0.79-1.75; P=0.65) or continuous atrial overdrive pacing ON versus OFF (hazard ratio=1.17; 95% confidence interval, 0.79-1.74; P=0.69) did not prevent the development of persistent AF. CONCLUSIONS In patients with paroxysmal AF and sick sinus syndrome requiring pacemaker implantation, an alternative atrial pacing site at the RA septum or continuous atrial overdrive pacing did not prevent the development of persistent AF. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. UNIQUE IDENTIFIER: NCT00419640.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right versus left atrial pacing in patients with sick sinus syndrome and paroxysmal atrial fibrillation (Riverleft study): study protocol for randomized controlled trial

BACKGROUND The incidence of sick sinus syndrome will increase due to population ageing. Consequently, this will result in an increase in the number of pacemaker implantations. The atrial lead is usually implanted in the right atrial appendage, but this position may be ineffective for prevention of atrial fibrillation. It has been suggested that pacing distally in the coronary sinus might be mor...

متن کامل

[Clinical safety and efficacy of single-chamber atrial pacing in sick sinus syndrome: long-term follow-up].

INTRODUCTION AND OBJECTIVES Although atrial pacing is a more physiological mode of stimulation in sinus node dysfunction, the pacing modes most often are used DDD and VVI. The aim of our study was to demonstrate that AAI/AAIR pacing is effective and safe by analyzing the complications and mortality of this pacing mode in a long-term follow-up study. PATIENTS AND METHOD Between 1982 and 2000 d...

متن کامل

Effects Of Fast Pathway Ablation On The Concealment Zone And Electrophysiological Behavior Of AV-Node During Atrial Fibrillation.

Objectives: Dual pathways have a determinant role in the occurrence of atrio nodal tachyarrhythmia (AVNRT). The aim of present study is to determine the role of slow pathway (SP) in the concealment zone and protective role of AV node during atrial fibrillation (AF). Material &Methods: In 7 isolated nodal rabbit preparation zone of concealment and concealed conduction is quantified by Specif...

متن کامل

Evaluation of bi-atrial pacing and single site right atrial pacing for the prevention of atrial fibrillation.

Atrial resynchronization resulting from simultaneous pacing of the atria may adjust inter- or intra-atrial asynchrony and prevent atrial fibrillation (AF). The purpose of this study was to assess the efficacy of bi-atrial pacing (BAP) in preventing AF, and the safety of this system. The effect of BAP was compared with single site right atrial pacing (RAP) in 6 patients with sick sinus syndrome ...

متن کامل

Long-term outcome of patients with drug-refractory atrial flutter and fibrillation after single- and dual-site right atrial pacing for arrhythmia prevention.

OBJECTIVES An initial crossover study comparing dual- and single-site right atrial pacing was performed followed by a long-term efficacy and safety evaluation of dual-site right atrial pacing in patients with drug-refractory atrial fibrillation (AF). Also examined was the efficacy of two single-site right atrial pacing modes (high right atrium and coronary sinus ostium) and the long-term need f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 128 7  شماره 

صفحات  -

تاریخ انتشار 2013