Liquid scintillation counters calibration stability over long timescales

نویسندگان

  • Pawel Gaca
  • Phillip E Warwick
  • Ian W Croudace
چکیده

Liquid scintillation spectrometry is widely used for the analysis of alpha and beta emitting radionuclides. Robust calibration of liquid scintillation (LS) spectrometers is fundamental to accurate LS measurement but at the same time is time consuming and costly, particularly if a wide range of radionuclides are analysed by the laboratory. The frequency of the calibration varies in different laboratories and is based on many practical and operational factors. This work summarizes the observations regarding variations in 1220 Quantulus spectrometers efficiency calibrations performed annually using various radionuclides: 3H 63Ni, 55Fe, 36Cl, 45Ca, 147Pm, 241Pu, 99Tc for a period of 9 years and discusses the implication to calibration frequency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standardization of 63Ni by 4πβ Liquid Scintillation Spectrometry With 3H-Standard Efficiency Tracing

The low energy (Eβmax = 66.945 keV ± 0.004 keV) β-emitter 63Ni has become increasingly important in the field of radionuclidic metrology. In addition to having a low β-endpoint energy, the relatively long half-life (101.1 a ± 1.4 a) makes it an appealing standard for such applications. This paper describes the recent preparation and calibration of a new solution Standard Reference Material of 6...

متن کامل

Scintillation Proximity Assay on the TopCount Microplate Scintillation Counter

The TopCountTM Microplate Scintillation Counter quantitates radioisotopes by liquid scintillation counting in standard microplate formats. Assays that previously had to be transferred from microplates to vials or to non-standard formats for counting can now be quantitated directly in microplates. TopCount can count up to 12 samples simultaneously with performance comparable to that of discrete ...

متن کامل

Counting Aqueous Samples with the TopCount Microplate Scintillation Counter

The TopCountTM Microplate Scintillation Counter quantitates radioisotopes by liquid scintillation counting in standard microplate formats. Assays that previously had to be transferred from microplates to vials or to non-standard formats for counting can now be quantitated directly in microplates. TopCount can count up to 12 samples simultaneously with performance comparable to that of discrete ...

متن کامل

Tritium Determination in Danube River Water in Serbia by Liquid Scintillation Counter

Tritium activity concentration in Danube river water in Serbia has been determinate using a liquid scintillation counter Quantulus 1220. During December 2010, water samples were taken along the entire course of Danube through Serbia, from HungarianSerbian to Romanian-Serbian border. This investigation is very important because of the nearness of nuclear reactor Paks in Hungary. Sample preparati...

متن کامل

Comparison of the Quantulus 1220 and 300SL Liquid Scintillation Counters for the Analysis of Rn in Groundwater

Background: Liquid scintillation counters (LSCs) are commonly used as an analytical method for detecting 222Rn in groundwater because they involve a simple sample pretreatment and allow high throughout with an autosampler. The Quantulus 1220 is the best-selling LSC in Korea, but its production was stopped. Recently, a new type of LSC, the 300SL, was introduced. In this study, the 300SL was comp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 314  شماره 

صفحات  -

تاریخ انتشار 2017