Retention Time Reproducibility of the Agilent 6890 Plus GC

ثبت نشده
چکیده

Agilent Technologies tested a large number of 6890 Plus gas chromatographs (GCs) over a 10-month period to characterize analytical performance. A sequence of ten runs was performed on each GC to measure retention time reproducibility. The results for retention time reproducibility show that a given peak typically falls within a very tight range of 0.002 to 0.003 min. The average standard deviation for all GCs tested was 0.001 min. This represents a relative standard deviation of less than 0.02 percent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Nitroaromatics and Nitro-Polycyclic Aromatic Hydrocarbons by Capillary Gas Chromatography with the Agilent 6890 Micro-ECD (5965-8015E)

A new electron capture detector (ECD) for the Agilent 6890 Series gas chromatograph (GC) allows very sensitive detection of nitroaromatic compounds at low picogram levels with a linear response over three orders of magnitude. Analysis of Nitroaromatics and Nitro-Polycyclic Aromatic Hydrocarbons by Capillary Gas Chromatography with the Agilent 6890 Micro-ECD This application note describes the p...

متن کامل

Energy and chemicals

Samples containing buprenorphine and derivatives were extracted using Agilent sample prep and analyzed by gas chromatography using an Agilent J&W HP-5 column. Published by Elsevier B. V. An empirical study on the selection of analytes and corresponding cutoffs for immunoassay and GC–MS in a two-step test strategy—buprenorphine example Analyst, 9, 1848-1856 (2009) Meng-Yan Wu et al. Tags HP-5, c...

متن کامل

Enhanced Essential Oils Analysis Using a High Performance Benchtop GC/MS System Application Note

A gas chromatograph (GC) coupled with a mass spectrometer (MS) forms a powerful tool for high quality quantitative and qualitative analysis. However, GC/MS analysis of complex mixtures such as essential oils often is a time-consuming task due to limitations in techniques and instrumentation. Faster analyses of these mixtures are possible by coupling the 5973A mass selective detector (MSD) with ...

متن کامل

Determination of Polybrominated Diphenyl Ethers in Polymeric Materials Using the 6890 GC/5973N inert MSD with Electron Impact Ionization Application

Due to their ubiquitous appearance in the ecosphere, various polybrominated diphenyl ether formulations have been banned. A major application of PBDEs is to impart fire retardancy to plastics used in electronics and electrical applications. This application note details an approach to determining the PBDEs present in the technical formulations in polymers. The instrumental analysis uses GC/MS w...

متن کامل

Automated Clean-up for Mineral Oil (Hydrocarbon Oil Index) Analysis using the Agilent 7696A Sample Prep WorkBench

Mineral oil (or Hydrocarbon oil) in water samples is determined by liquid-liquid extraction, followed by a clean-up step on Florisil, and GC-FID analysis. Using the Agilent 7696A Sample Prep WorkBench system, drying and clean-up of samples obtained after liquid-liquid extraction can be automated. High recoveries and excellent reproducibility are obtained for the mineral oil fraction, while the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000