We correct an error in our previous paper [Biomed. Opt. Express 2, 1218 (2011)] which led to an erroneous conclusion that a dispersive optical delay line (DODL) used in a swept source optical coherence tomography (SSOCT) system generated a pure phase modulation allowing for complex conjugate artifact removal in Fourier domain OCT via optical heterodyning. We now understand that an alternate phenomenon known as coherence revival was responsible for the observed phase modulation, while the DODL provided a compact means of generating a large group delay with readily adjustable group velocity dispersion compensation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complete complex conjugate resolved heterodyne swept-source optical coherence tomography using a dispersive optical delay line

Swept-source optical coherence tomography (SSOCT) provides a substantial sensitivity advantage over its time-domain counterpart, but suffers from a reduced imaging depth range due to sensitivity falloff and complex conjugate ambiguity. Heterodyne complex conjugate-resolved SSOCT (HCCR-SSOCT) has been previously demonstrated as a technique to completely resolve the complex conjugate ambiguity, e...

متن کامل

Complex conjugate resolved heterodyne swept source optical coherence tomography using coherence revival

We describe a simple and low-cost technique for resolving the complex conjugate ambiguity in Fourier domain optical coherence tomography (OCT) that is applicable to many swept source OCT (SSOCT) systems. First, we review the principles of coherence revival, wherein an interferometer illuminated by an external cavity tunable laser (ECTL) exhibits interference fringes when the two arms of the int...

متن کامل

Full-range swept source optical coherence tomography based on carrier frequency by transmissive dispersive optical delay line.

A high speed swept source optical coherence tomography (SS-OCT) system capable of full-range imaging is presented. Wave-number carrier frequency is introduced into the spectral interference signal by a transmissive dispersive optical delay line (TDODL). High carrier frequency in the spectral interference signal corresponding to an equivalent distance-shift is exploited to obtain full-range OCT ...

متن کامل

Instantaneous complex conjugate resolved spectral domain and swept-source OCT using 3x3 fiber couplers.

We report that the complex conjugate artifact in Fourier domain optical coherence tomography approaches (including spectral domain and swept source OCT) may be resolved by the use of novel interferometer designs based on 3x3 and higher order fiber couplers. Interferometers built from NxN (N>2) truly fused fiber couplers provide simultaneous access to non-complementary phase components of the co...

متن کامل

Imaging limbal and scleral vasculature using Swept Source Optical Coherence Tomography.

We demonstrate an application of high-speed swept source optical coherence tomography for vessel visualization in the anterior segment of the human eye. The human corneo-scleral junction and sclera was imaged in vivo. Imaging was performed using a swept source OCT system operating at the 1050nm wavelength range and 100kHz A-scan rate. High imaging speed enables the generation of 3D depth-resolv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2012