Best practices to minimize risk of infection with intrauterine device insertion.
نویسندگان
چکیده
BACKGROUND Intrauterine devices provide an extremely effective, long-term form of contraception that has the benefit of being reversible. Historically, the use of certain intrauterine devices was associated with increased risk of pelvic inflammatory disease. More recent evidence suggests that newer devices do not carry the same threat; however, certain risk factors can increase the possibility of infection. OBJECTIVES To review the risk of infection with the insertion of intrauterine devices and recommend strategies to prevent infection. OUTCOMES The outcomes considered were the risk of pelvic inflammatory disease, the impact of screening for bacterial vaginosis and sexually transmitted infections including chlamydia and gonorrhea; and the role of prophylactic antibiotics. EVIDENCE Published literature was retrieved through searches of PubMed, Embase, and The Cochrane Library on July 21, 2011, using appropriate controlled vocabulary (e.g., intrauterine devices, pelvic inflammatory disease) and key words (e.g., adnexitis, endometritis, IUD). An etiological filter was applied in PubMed. The search was limited to the years 2000 forward. There were no language restrictions. Grey (unpublished) literature was identified through searching the web sites of national and international medical specialty societies. VALUES The quality of evidence in this document was rated using the criteria described in the Report of the Canadian Task Force on Preventative Health Care (Table). Recommendations 1. All women requesting an intrauterine device should be counselled about the small increased risk of pelvic inflammatory disease in the first 20 days after insertion. (II-2A) 2. All women requesting an intrauterine device should be screened by both history and physical examination for their risk of sexually transmitted infection. Women at increased risk should be tested prior to or at the time of insertion; however, it is not necessary to delay insertion until results are returned. (II-2B) 3. Not enough current evidence is available to support routine screening for bacterial vaginosis at the time of insertion of an intrauterine device in asymptomatic women. (II-2C) 4. Routine use of prophylactic antibiotics is not recommended prior to intrauterine device insertion, although it may be used in certain high-risk situations. (I-C) 5. Standard practice includes cleansing the cervix and sterilizing any instruments that will be used prior to and during insertion of an intrauterine device. (III-C) 6. In treating mild to moderate pelvic inflammatory disease, it is not necessary to remove the intrauterine device during treatment unless the patient requests removal or there is no clinical improvement after 72 hours of appropriate antibiotic treatment. In cases of severe pelvic inflammatory disease, consideration can be given to removing the intrauterine device after an appropriate antibiotic regimen has been started. (I-B) 7. An intrauterine device is a safe, effective option for contraception in an HIV-positive woman. (I-B) 8. An intrauterine device can be considered a first-line contraceptive agent in adolescents. (I-A).
منابع مشابه
Does insertion and use of an intrauterine device increase the risk of pelvic inflammatory disease among women with sexually transmitted infection? A systematic review.
Concerns exist as to whether the insertion of copper and levonorgestrel-releasing intrauterine devices (IUDs) increases the risk of pelvic inflammatory disease (PID) among women with sexually transmitted infection (STI). We searched the MEDLINE database for all articles published between January 1966 and March 2005 that included evidence relevant to IUDs and STIs and PID. None of the studies th...
متن کاملO-32: Pain Experienced during Sonohysterography :Cervical to Uterine Catheter Placement
Background: The aim of this study is to evaluate whether the location of the balloon placement into either the cervical canal or uterine cavity during sonohysterography can affect the intensity of pain. Materials and Methods: A total of 300 infertile women undergoing sonohysterography were randomized to intracervical or intrauterine balloon placement. The examination was scheduled in the early ...
متن کاملSide effects of Intrauterine Device in Breast and Bottle Feeding Mothers
Dear Editor, Implementing health and family planning programs is the most effective way for birth control. Intrauterine device (IUD) is an effective long-acting contraceptive mean.1 Considering little side effects and good compatibility of IUD to physiologic hormonal alterations occurring during breast feeding, the device is an acceptable contraceptive mean in nursing mothers.2In spite of its a...
متن کاملAnalgesia and anesthesia during IUD insertion: local anesthetics
Background: Intrauterine Device (IUD) is an effective and long term method of contraception that can be used without continued effort by the user to prevent pregnancy perfectly. Pain during IUD insertion is one of the obstacles to properly using the device. Thus, using different methods of analgesia and anesthesia to alleviate this pain has been studied by many researchers. This review article ...
متن کاملTubo-Ovarian Abscess Formation in Users of Intrauterine Devices Remote From Insertion: A Report of Three Cases
BACKGROUND The association between tubo-ovarian abscess formation and the presence of an intrauterine device (IUD) is well recognized. It has been suggested that the risk of upper-genital-tract infection is highest during the immediate period following the insertion of an IUD, returning to baseline by 5 months postinsertion. We present 3 cases of women who, 10-21 years after insertion of their ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of obstetrics and gynaecology Canada : JOGC = Journal d'obstetrique et gynecologie du Canada : JOGC
دوره 36 3 شماره
صفحات -
تاریخ انتشار 2014