Pulse oximetry is a technique of fetal monitoring during labour based on non-invasive measurement of fetal arterial oxygen saturation. It has been shown in animal studies that metabolic acidosis occurred for a fetal arterial oxygen saturation below 30%. One of the main debates during initial experience in humans, was focused on the adequate cut-off for intervention (or non-intervention), and the duration of time below this threshold. Most of the data feeding this debate came from Europe where it was generally felt that determining an adequate cut-off was a prerequisite to the design of randomised trials.
منابع مشابه
Accuracy of fetal pulse oximetry and pitfalls in measurements.
Pulse oximetry is a technique for estimating arterial oxygen saturation continuously and non-invasively. Reflectance pulse oximetry might become useful for monitoring the fetus during labour but it is much more susceptible to all kinds of physiological variations than the well-established transmission pulse oximetry for neonatal or adult monitoring. This review focuses on the accuracy of reflec...
متن کاملEvaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals
Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...
متن کاملEvaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals
Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...
متن کاملFetal transabdominal pulse oximeter studies using a hypoxic sheep model.
OBJECTIVE This study investigates the validity of transabdominal pulse oximetry using a sheep fetal hypoxia model with fetal arterial hemoglobin saturation. METHODS Four pregnant ewes were anaesthetized and cannulated through the brachial artery to measure direct arterial blood saturation, SaO(2). Next, the transabdominal pulse oximeter was used to measure indirect measurement of the arterial...
متن کاملEffectiveness of pulse oximetry versus fetal electrocardiography for the intrapartum evaluation of nonreassuring fetal heart rate.
OBJECTIVES To compare the effectiveness of pulse oximetry and fetal electrocardiography in the management of labor with nonreassuring fetal heart rate (NRFHR). STUDY DESIGN This randomized experimental study consisted of two arms. In group 1 we used pulse oximetry and in group 2 we used STAN® technology. The participants in each group were 90 pregnant women with a full-term singleton fetus in...