Orbital blowout fractures: experimental evidence for the pure hydraulic theory.
نویسندگان
چکیده
BACKGROUND The mechanism of injury and the underlying biomechanics of orbital blowout fractures remain controversial. The "hydraulic" theory proposes that a generalized increased orbital content pressure results in direct compression and fracturing of the thin orbital bone. OBJECTIVE To examine the pure hydraulic mechanism of injury by eliminating the factor of globe-to-wall contact and its possible contribution to fracture thresholds and patterns. MATERIALS AND METHODS Five fresh human cadaver specimens were used for the study. In each cadaver head, 1 orbit was prepared to mimic the normal physiologic condition by increasing the hypotony of the cadaver globe to normal intraocular pressure (15-20 mm Hg) with intravitreous injection of isotonic sodium chloride solution (saline). The second orbit served as a "hydraulic control," whereby the globe and orbital contents were exenterated and replaced by a saline-filled balloon at physiologic intraocular pressure. A 1-kg pendulum measuring 2.5 cm in diameter was used to strike the cadaver heads. Drop heights ranged from 0.2 m to 1.1 m (1960 mJ to 10 780 mJ energy). Each head was struck twice, once to each orbit. Direct visualization, high-speed videography, and computed tomographic scans were used to determine injury patterns at various heights between the 2 orbits. RESULTS A fracture threshold was found at a drop height of 0.3 m (2940 mJ). Fracture severity and displacement increased with incremental increases in drop height (energy). Fracture displacement, with herniation of orbital contents, was obtained at heights above 0.5 m (4900 mJ). Isolated orbital floor fractures were obtained at lower heights, with medial wall fractures occurring in conjunction with floor fractures at higher energies (> or =6860 mJ). The globe intact side and balloon (hydraulic control) side showed nearly identical fracture patterns and levels of displacement at each drop height. CONCLUSIONS This study provides support for the "hydraulic" theory and evidence against the role of direct globe-to-wall contact in the pathogenesis of orbital blowout fractures. In addition, the orbital floor was found to have a lower threshold for fracture than the medial wall. Preliminary threshold values for fracture occurrence and soft tissue displacement were obtained.
منابع مشابه
Orbital volume measurement in the management of pure blowout fractures of the orbital floor.
With the recent advent of accurate orbital volume assessment by computed tomography, a retrospective analysis was made of 31 patients with 'pure' blowout fracture of the orbital floor, managed either surgically or conservatively, to determine whether orbital volume measurement could provide an additional parameter of use in the management of such fractures. There was a significant difference in...
متن کاملPrevalence of Diplopia and Extraocular Movement Limitation according to the Location of Isolated Pure Blowout Fractures
BACKGROUND Isolated pure blowout fractures are clinically important because they are the main cause of serious complications such as diplopia and limitation of extraocular movement. Many reports have described the incidence of blowout fractures associated with diplopia and limitation of extraocular movement; however, no studies have statistically analyzed this relationship. The purpose of this ...
متن کاملOrbital Wall Restoring Surgery in Pure Blowout Fractures
BACKGROUND Restoring orbital volume in large blowout fractures is still a technically challenge to the orbital surgeon. In this study, we restored the orbital wall using the combination of transorbital and transnasal approach with additional supports from the paranasal sinuses, and we compared the surgical outcome to that of a conventional transorbital method. METHODS A retrospective review o...
متن کاملImpact of surgical timing of postoperative ocular motility in orbital blowout fractures
PURPOSE To investigate the surgical timing postinjury in regard to ocular motility in patients with orbital-floor blowout fractures. METHODS This study involved 197 eyes (92 right eyes and 105 left eyes) of 197 patients (154 males and 43 females, mean age: 29.0 years, range: 7-85 years) with pure orbital blowout fractures. All patients underwent surgical repair within 30 days postinjury and w...
متن کاملEndoscopic endonasal repair of orbital floor fracture.
BACKGROUND High-resolution endoscopes and the advent of endoscopic instruments for sinus surgery provide surgeons with excellent endonasal visualization and access to the orbital walls. OBJECTIVE To demonstrate repair of orbital floor blowout fractures through an intranasal endoscopic approach that allows repair of the orbital floor fracture and elevation of the orbital content using a balloo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of facial plastic surgery
دوره 4 2 شماره
صفحات -
تاریخ انتشار 2002