Analysis of eddy currents induced by transverse and longitudinal gradient coils in different tungsten collimators geometries for SPECT/MRI integration.
نویسندگان
چکیده
PURPOSE We investigated the temporal variation of the induced magnetic field due to the transverse and the longitudinal gradient coils in tungsten collimators arranged in hexagonal and pentagonal geometries with and without gaps between the collimators. METHODS We modeled x-, y-, and z-gradient coils and different arrangements of single-photon emission computed tomography (SPECT) collimators using FEKO, a three-dimensional electromagnetic simulation tool. A time analysis approach was used to generate the pulsed magnetic field gradient. The approach was validated with measurements using a 7T MRI scanner. RESULTS Simulations showed an induced magnetic field representing 4.66% and 0.87% of the applied gradient field (gradient strength = 500 mT/m) for longitudinal and transverse gradient coils, respectively. These values can be reduced by 75% by adding gaps between the collimators for the pentagonal arrangement, bringing the maximum induced magnetic field to less than 2% of the applied gradient for all of the gradient coils. CONCLUSION Characterization of the maximum induced magnetic field shows that by adding gaps between the collimators for an integrated SPECT/MRI system, eddy currents can be corrected by the MRI system to avoid artifact. The numerical model was validated and was proposed as a tool for studying the effect of a SPECT collimator within the MRI gradient coils.
منابع مشابه
Analysis and reduction of eddy current effects induced by tesseral end zonal gradient coils in different collimator geometries for SPECT/MRI integration
INTEC, Ghent University/iMinds, Ghent, Belgium SPECT and MRI each have their respective advantages and limitations. Combining these two technologies in a synergistic manner allows researchers to exploit the strengths of both techniques but also result in disturbing eddy currents. In this paper, we studied the temporal variation of the induced magnetic field due to the transverse and longitudina...
متن کاملErratum to: Analysis and reduction of eddy current effects induced by tesseral end zonal gradient coils in different collimator geometries for SPECT/MRI integration
et al. Analysis and reduction of eddy current effects induced by tesseral end zonal gradient coils in different collimator geometries for SPECT/MRI integration. permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
متن کاملTemporal analysis of Z-Gradient coil eddy currents in tungsten collimator with different resistivities for SPECT/MRI
INTEC, Ghent University/iMinds, Ghent, Belgium Combining Single Photon Emission Computed Tomography (SPECT) with Magnetic Resonance Imaging (MRI) results in an interaction of the time-varying magnetic field gradients with the highly conducting tungsten collimator, which generates a secondary magnetic field causing spatial distortions in reconstructed MR images. Accurate simulations are importan...
متن کاملFDTD Analysis of transient eddy currents induced by gradient coil switching in MRI
A. Trakic, H. Wang, F. Liu, H. S. Lopez, S. Crozier School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, QLD, Australia Synopsis: Most Magnetic Resonance Imaging (MRI) spatial encoding techniques employ low-frequency pulsed magnetic field gradients that undesirably induce multi-exponentially decaying eddy currents in nearby conducting structures o...
متن کاملEigenmode Analysis of Eddy Currents and Eigenmode Coil Design
Introduction Eddy currents have long been the bane of MRI. Particularly since the mid 1980s when imaging sequences became more rapid [1] and superconducting magnets became routinely used. When gradient coils are switched rapidly, eddy currents are induced in the cryostat vessel and other surrounding conducting structures. Two principal solutions have been adopted into standard practice for deal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 74 6 شماره
صفحات -
تاریخ انتشار 2015