Synchrotron radiation μCT and histology evaluation of bone-to-implant contact.

نویسندگان

  • Camilla Albeck Neldam
  • Jon Sporring
  • Alexander Rack
  • Torsten Lauridsen
  • Ellen-Margrethe Hauge
  • Henrik L Jørgensen
  • Niklas Rye Jørgensen
  • Robert Feidenhansl
  • Else Marie Pinholt
چکیده

The purpose of this study was to evaluate bone-to-implant contact (BIC) in two-dimensional (2D) histology compared to high-resolution three-dimensional (3D) synchrotron radiation micro computed tomography (SR micro-CT). High spatial resolution, excellent signal-to-noise ratio, and contrast establish SR micro-CT as the leading imaging modality for hard X-ray microtomography. Using SR micro-CT at voxel size 5 μm in an experimental goat mandible model, no statistically significant difference was found between the different treatment modalities nor between recipient and reconstructed bone. The histological evaluation showed a statistically significant difference between BIC in reconstructed and recipient bone (p < 0.0001). Further, no statistically significant difference was found between the different treatment modalities which we found was due to large variation and subsequently due to low power. Comparing histology and SR micro-CT evaluation a bias of 5.2% was found in reconstructed area, and 15.3% in recipient bone. We conclude that for evaluation of BIC with histology and SR micro-CT, SR micro-CT cannot be proven more precise than histology for evaluation of BIC, however, with this SR micro-CT method, one histologic bone section is comparable to the 3D evaluation. Further, the two methods complement each other with knowledge on BIC in 2D and 3D.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Osseointegration around Tibial Implants in Rats by Ibandronate-Treated Nanotubular Ti-32Nb-5Zr Alloy

Materials with differing surfaces have been developed for clinical implant therapy in dentistry and orthopedics. This study was designed to evaluate bone response to titanium alloy containing Ti-32Nb-5Zr with nanostructure, anodic oxidation, heat treatment, and ibandronate coating. Rats were randomly assigned to two groups for implantation of titanium alloy (untreated) as the control group and ...

متن کامل

Osseointegration assessment of dental implants using a synchrotron radiation imaging technique: a preliminary study.

PURPOSE This study tests the possibility of using synchrotron radiation (SR) x-ray micro-imaging as a new method to evaluate osseointegration. MATERIALS AND METHODS A simple imaging setup with primarily unmonochromatic SR was used to study the interface of a dental implant in contact with bone. The samples were prepared by sectioning the undecalcified specimen of a titanium screw implanted in...

متن کامل

The Use of Light/Chemically-Hardened Poly-Methyl-Methacrylate, Poly-Hydroxyl-Ethyl-Methacrylate and Calcium Hydroxide Graft Material in Combination with Polyanhydride around Implants and Extraction Sockets in Minipigs: Part II: Histological and μCT Evaluations

Methods: Light-hardened poly-methyl-methacrylate, poly-hydroxyl-ethyl-methacrylate, and calcium hydroxide plus polyanhydride (PPCH+PA) composite graft), PPCH graft alone, PA graft alone, were compared to each other and to a no graft control group. All mandibular premolar teeth were extracted; a total of 48 implants were placed into sockets of the mesial roots in three minipigs. Crestal areas an...

متن کامل

تحلیل پایداری ایمپلنت دندانی و بررسی تاثیر عوامل موثر بر اتصال ایمپلنت- استخوان به کمک مدل اصطکاکی تماس

Background and Aims: Relative displacement of the implant with respect to bone and quality of bone-implant contact play critical roles in the dental implant stability. The goal of this study was to investigate the dental implant stability using non-linear finite elements method. Therefore, bone-implant relative displacement due to applied force to the implant was calculated, and then an appropr...

متن کامل

Comparison of bone-implant contact and bone-implant volume between 2D-histological sections and 3D-SRµCT slices.

Histological imaging is still considered the gold standard for analysing bone formation around metallic implants. Generally, a limited number of histological sections per sample are used for the approximation of mean values of peri-implant bone formation. In this study we compared statistically the results of bone-implant contact (BIC) and bone-implant volume (BIV) obtained by histological sect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery

دوره 45 9  شماره 

صفحات  -

تاریخ انتشار 2017