Subsidence in Collarless Corail Hip Replacement

نویسندگان

  • Veenesh Selvaratnam
  • Vishwanath Shetty
  • Vishal Sahni
چکیده

The purpose of this study was to assess whether subsidence occurs in collarless Corail hip replacement (CCHR) and to ascertain the extent and timing of subsidence if present. Retrospective case notes analysis was performed. Sixty eight patients who had CCHR were identified from our database. Male to female ratio was 32:36. Their mean age was 74.2 years (range 37-95 years). Indications for surgery were osteoarthritis in 64 (94%) patients, rheumatoid arthritis in two (3%) patients and avascular necrosis in two (3%) patients. Subsidence was measured at 6 weeks, 6 months and 1 year post-op compared to initial post-op x-rays. At 6 weeks x-ray 21 patients did not have any subsidence, 18 patients had 1 millimeter (mm) subsidence, 10 patients had 2mms subsidence, 4 patients had 3mms subsidence, 5 patients had 4mms subsidence, 1 patient had 5mms subsidence, 4 patients had 6 mms subsidence and 1 patient each had subsidence of 7mms, 9mms, 11mms, 13mms and 26 mms respectively. When compared with 6 months x-rays only 2 patients had a further subsidence of 2mms while another patient had 3mms subsidence. No further subsidence occurred at 1 year follow up x-rays. One patient had revision surgery due to symptomatic subsidence (29mms) at 6 months follow up. Subsidence does occur in the first 6 weeks in collarless Corail hip replacement, and to a lesser extent until 6 months postoperatively, but does not progress further.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Revision total hip replacement using cemented collarless double-taper femoral components.

We investigated 219 revisions of total hip replacement (THR) in 211 patients using a collarless double-taper cemented femoral component. The mean age of the patients was 72 years (30 to 90). The 137 long and 82 standard length stems were analysed separately. The mean follow-up was six years (2 to 18), and no patient was lost to follow-up. Survival of the long stems to re-revision for aseptic lo...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Femoral impaction bone allografting with an Exeter cemented collarless, polished, tapered stem in revision hip replacement: a mean follow-up of 10.5 years.

Femoral impaction bone allografting has been developed as a means of restoring bone stock in revision total hip replacement. We report the results of 75 consecutive patients (75 hips) with a mean age of 68 years (35 to 87) who underwent impaction grafting using the Exeter collarless, polished, tapered femoral stem between 1992 and 1998. The mean follow-up period was 10.5 years (6.3 to 14.1). Th...

متن کامل

Collarless polished tapered stem: clinical and radiological results at a minimum of ten years' follow-up.

We retrospectively reviewed 175 patients (191 hips) who had undergone primary cemented total hip replacement between November 1992 and November 1995 using a collarless polished double-tapered femoral component after a minimum of ten years (mean 11.08; 10 to 12.8). All stems were implanted using contemporary cementing techniques with a distal cement restrictor, pressurised lavage, retrograde cem...

متن کامل

Is stem design important in uncemented total hip replacement to decrease subsidence in obese patients?

© Annals of Joint. All rights reserved. Ann Joint 2017;2:50 aoj.amegroups.com There has been a world-wide trend towards cementless total hip replacement (THR) over the last 20 years (1). One of the primary reasons for the introduction of the cementless stem was to improve the outcome in younger, more active patients, particularly males. The New Zealand Joint Registry (NZJR) has shown a revision...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015