Poor survival of ABG I hip prosthesis in younger patients.

نویسندگان

  • Jiri Gallo
  • Katerina Langova
  • Vitezslav Havranek
  • Ivana Cechova
چکیده

BACKGROUND Hydroxyapatite coated (HAC) hip implants have been used in clinical practice for more than two decades. However, the majority of studies have reported only intermediate term outcomes that are not reliable for predicting long-term behavior in all implants. The aim of this study was to determine the performance of HAC total hip arthroplasty in younger patients over a 10-year follow-up period. METHODS AND RESULTS This was an observational retrospective study of a 137 consecutive hips with the ABG I prosthesis. Of these, 128 were available for the last investigation. Median duration of follow-up was 10.9 years. The mean age at time of index surgery was 46+/-6.7 years. Probability of implant survival was estimated using the Kaplan-Meier method. The overall 12-year cumulative survival was 0.55 (95% CI, 0.443-0.659). Periprosthetic osteolysis (57 %) was the most frequent reason for failure followed by aseptic loosening (28 %). When only aseptic loosening was included in the analysis, the same figures for cup and stem were 0.873 (95% CI, 0.808-0.938) and 0.992 (95% CI, 0.976- 1.0), respectively. Patients with a smaller cup size were those at high risk for revision due to wear-related complications (odds ratio, OR=4.3; 95% CI, 1.734-10.555). CONCLUSION This study reports one of the poorest 12-year survivorship data for cementless acetabular component in the literature. The main reason for premature failure was osteolysis, strongly related to high wear rate of polyethylene.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Hydroxyapatite-coated stems in total hip arthroplasty after a minimum 10-years follow-up.

PURPOSE OF THE STUDY Hydroxypatite coating (HAC) was introduced into total hip arthroplasty (THA) practice to improve the fixation interface between bone and prosthesis. To test this assumption however, long-term follow-up investigations are needed. In this study, we present data for two consecutive series of THA stems with HAC and a minimum ten-year follow-up. MATERIAL Overall, 249 patients (2...

متن کامل

Premature wear and osteolysis in an HA-coated, uncemented total hip arthroplasty.

The ABG I cementless hip prosthesis has demonstrated unacceptably high rates of wear and osteolysis in our patients. We performed a retrospective study of 97 hips implanted between 1992 and 1998. Radiographic analysis revealed high rates of wear of the polyethylene liner with marked peri-acetabular osteolysis. Clinical examination indicated that many of these patients were initially asymptomati...

متن کامل

Male gender, Charnley class C, and severity of bone defects predict the risk for aseptic loosening in the cup of ABG I hip arthroplasty

BACKGROUND We studied which factor could predict aseptic loosening in ABG I hip prosthesis with hydroxyapatite coating. Aseptic loosening and periprosthetic osteolysis are believed to be caused, at least in part, by increased polyethylene (PE) wear rate via particle disease. Based on it, increased PE wear rate should be associated with aseptic loosening regardless of the type of implant. METH...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

Hip Arthroplasty and its Revision in a Child: Case Report and Literature Review

Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia

دوره 152 1  شماره 

صفحات  -

تاریخ انتشار 2008