Partial Discharge Monitoring of Power Transformers by UHF Sensors
نویسنده
چکیده
The reliability of electrical energy networks depends on both, the quality and the reliability of its electrical equipment, e.g. power transformers. Local failures inside their insulation can lead to breakdowns and hence to high outage and penalty costs. Usually, power transformers are tested on partial discharge (PD) activity before commissioning. UHF PD monitoring can be used to prevent these events during service. Continuous monitoring exceeds the benefits of singular diagnostic measurements. Diagnostic PD measurements can provide snapshot information but no trend information. Also, temporary measurements can cause misleading interpretations due to the volatile nature of PD as measurements performed during low PD activity do not prove the general absence of PD. These drawbacks can be avoided by using continuous PD monitoring. In the first part, this contribution presents two different types of ultra-high frequency (UHF) sensors for PD measurement and their installation at power transformers including an UHF PD monitoring system. The second part is about a use case providing three years of UHF PD monitoring data of a power transformer, where the PD data is correlated with the transformer’s load, temperature and the dissolved gas analysis.
منابع مشابه
An Intelligent Sensor for the Ultra-High-Frequency Partial Discharge Online Monitoring of Power Transformers
Ultra-high-frequency (UHF) partial discharge (PD) online monitoring is an effective way to inspect potential faults and insulation defects in power transformers. The construction of UHF PD online monitoring system is a challenge because of the high-frequency and wide-frequency band of the UHF PD signal. This paper presents a novel, intelligent sensor for UHF PD online monitoring based on a new ...
متن کاملCalibration of UHF Partial Discharge Measurement for Power Transformers And a Comparison to the Calibration of Electrical PD Measurement
The reliability of electrical energy networks depends on the quality and reliability of its electrical equipment, e.g. power transformers. Local failures inside their insulation may lead to catastrophic breakdowns and may cause high outage and penalty costs. To prevent these destroying events, power transformers can be tested on partial discharge (PD) activity before commissioning and monitored...
متن کاملTE-Monitoring von Leistungstransformatoren mittels UHF Sensoren
The reliability of electrical energy networks depends on both the quality and the reliability of its electrical equipment, e.g. power transformers. Local failures inside their insulation can lead to breakdowns and hence to high outage and penalty costs. Usually, power transformers are tested on partial discharge (PD) activity before commissioning. UHF PD monitoring can be used to prevent these ...
متن کاملبررسی عملکرد پروبهای UHF در آشکارسازی تخلیه جزئی در ترانسفورماتورهای فشار قوی
Recently, UHF partial discharge (PD) detection on power transformers attracts lots of attentions. For the transformers already installed in power network, the UHF signals can be captured only by UHF probes installed through oil drain valve. Although UHF probes are commercially produced, there are a lot of missing information on characteristics and features of these probes for PD detection. In t...
متن کاملUhf Monitoring of Partial Discharge in Substation Equipment Using a Novel Multi-sensor Cable Loop
This paper describes the development of a partial discharge measurement system that utilises a multiplexed approach to ultra-high-frequency monitoring on many pieces of equipment using a single cable loop connected to only two sampling channels. It is envisioned that the system could be used in partial discharge monitoring of medium voltage metal-enclosed switchgear, or several power transforme...
متن کامل