0 Precision measurements of sodium - sodium and sodium - noble gas molecular absorption
نویسندگان
چکیده
Experimental apparatus and measurement technique are described for precision absorption measurements in sodium-noble gas mixtures. The absolute absorption coefficient is measured in the wavelength range from 425 nm to 760 nm with ±2% uncertainty and spectral resolution of 0.02 nm. The precision is achieved by using a specially designed absorption cell with an accurately defined absorption path length, low noise CCD detector and double-beam absorption measurement scheme. The experimental setup and the cell design details are given. Measurements of sodium atomic number density with ±5% uncertainty complement absorption coefficient measurements and allow derivation of the reduced absorption coefficients for certain spectral features. The sodium atomic number density is measured using the anomalous dispersion method. The accuracy of this method is improved by employing a least-squares fit to the interference image recorded with CCD detector and the details of this technique are given. The measurements are 1 aimed at stringent testing of theoretical calculations and improving the values of molecular parameters used in calculations.
منابع مشابه
An Experimental Investigation of Reactive Absorption of Carbon Dioxide into an Aqueous NH3/H2O/NaOH Solution
In this research, the reactive absorption of carbon dioxide in an aqueous solution of NH3, H2O, and NaOH has experimentally been investigated. The experiments were carried out in an absorption pilot plant in different operational conditions. The composition and temperature of both gas and liquid phases were obtained during the column height. The concentration of molecular ...
متن کاملCollision-induced (2)P(1/2) - (2)P(3/2) mixing in sodium
The total cross sections for Inelastic collisions between excited sodium and noble gas atoms in their ground states, leading to 2 2 3 P^y2 — — 3 ^3/2 excitation transfer in sodium, have been determined in a series of sensitized fluorescence experiments with pure sodium vapour and its mixtures with noble gases. In the experiments with pure sodium, the sodium vapour pressure was varied over the r...
متن کاملGC-FID and HPLC-DAD Methods for the Determination of Menadione Sodium Bisulphite Directly and by Converting Menadione Sodium Bisulphite to Menadione in Pharmaceutical Preparation
GC-FID and HPLC-DAD were developed for determination of menadione (MN) and menadione sodium bisulphite (MSB). By means of each method, quantitative analysis of MSB in commercial pharmaceutical was performed in both direct analysis of MSB and analysis of MN by converting MSB to MN with sodium carbonate. GC-FID method was carried out on the HP-5 capillary column using nitrogen gas. HPLC-DAD metho...
متن کاملGC-FID and HPLC-DAD Methods for the Determination of Menadione Sodium Bisulphite Directly and by Converting Menadione Sodium Bisulphite to Menadione in Pharmaceutical Preparation
GC-FID and HPLC-DAD were developed for determination of menadione (MN) and menadione sodium bisulphite (MSB). By means of each method, quantitative analysis of MSB in commercial pharmaceutical was performed in both direct analysis of MSB and analysis of MN by converting MSB to MN with sodium carbonate. GC-FID method was carried out on the HP-5 capillary column using nitrogen gas. HPLC-DAD metho...
متن کاملRelaxation of the 4D3/2 and 4D5/2 levels of sodium atom perturbed by noble gases
2014 The sodium atom is excited selectively in the 4D3/2 or 4D5/2 level using Doppler-free two-photon absorption. We analyse the fluorescence in intensity and polarization in presence of noble gas atoms. We measure the cross-sections corresponding to the transfer of population between 4D3/2 and 4D5/2 and between 4D and 4F, the relaxation of alignment in both fine sublevels and the transfer of a...
متن کامل