Novel Validated Stability-Indicating UPLC Method for the Estimation of Naproxen and its Impurities in Bulk Drugs and Pharmaceutical Dosage Form

نویسندگان

  • Papanaboina Venkatarao
  • Morrisetty Nagendra Kumar
  • Maram Ravi Kumar
چکیده

A novel, reversed-phase ultra-performance liquid chromatographic method was developed and validated for the determination of related substances in Naproxen (NAP) bulk drugs and dosage forms. The related substances included degradation and process-related impurities. The method was developed using the Waters Acquity BEH C18 column using the gradient program with mobile phase A of a pH 7.0 phosphate buffer and methanol in the ratio of 90: 10 (v/v) and mobile phase B as methanol and acetonitrile in the ratio of 50:50 (v/v). Naproxen and its impurities were monitored at 260 nm. Naproxen was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal, humidity, and photolytic degradations. The degradation products were well-resolved from the main peak and its impurities, proving the stability-indicating power of the method. The performance of the method was validated according to the present ICH guidelines for specificity, limit of detection, limit of quantification, linearity, accuracy, precision, ruggedness, and robustness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability-indicating UFLC method for uncoupling and estimation of impurities in clopidogrel, aspirin and omeprazole in their tablet dosage form using PDA detection

In this paper a fast and novel stability-indicating ultra fast LC method for separation and estimation of impurities in clopidogrel and aspirin in their combined tablet dosage form and omeprazole was developed. The separation of USP related substances of clopidogrel (A, B and C), aspirin (D), omeprazole (A, B and C) and few other unknown impurities was detected by using ultra fast liquid chroma...

متن کامل

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...

متن کامل

A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form

A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...

متن کامل

A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form

A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...

متن کامل

A Novel, Validated Stability-Indicating UPLC Method for the Estimation of Lansoprazole and its Impurities in Bulk Drug and Pharmaceutical Dosage Forms

A novel, reversed-phase ultra-performance liquid chromatographic method was developed and validated for the determination of the assay and related substances of Lansoprazole (LAN) in bulk drug and capsule dosage forms. The related substances include degradation and process-related impurities. The method was developed using the Waters Acquity BEH C18 column and gradient program with mobile phase...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 80  شماره 

صفحات  -

تاریخ انتشار 2012