The fetal electrocardiogram: current clinical developments in Nottingham.

نویسنده

  • H G Murray
چکیده

The fetal electrocardiogram (FECG) has been recorded from 155 women in labor using a fetal scalp electrode and a minicomputerized enhanced averaging technique. Fetal hypoxia, acidosis, and stress have been diagnosed by analysis of blood from the fetal scalp, and post delivery from full gas analysis from blood taken from the umbilical artery and vein. Umbilical venous levels of serum lactate, adrenaline, noradrenaline, potassium and hemoglobin were also determined. A P wave was seen to be present in all cases recorded. The P-R interval correlated both with fetal autonomic nervous activity, and with the R-R interval of the healthy fetus. The P-R--R-R interval correlation altered with increasing fetal acidosis. QRS complex changes were varied and not usually related to fetal condition. ST segment changes occurred with increasing fetal acidosis. T wave analysis although incomplete, has shown no obvious correlation with fetal condition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of non-invasive fetal electrocardiography in diagnosing second-degree fetal atrioventricular block

BACKGROUND Complete atrioventricular block in fetuses is known to be mostly associated with autoimmune disease and can be irreversible if no steroids treatment is provided. Conventional methods used in clinical practice for diagnosing fetal arrhythmia are limited since they do not reflect the primary electrophysiological conduction processes that take place in the myocardium. The non-invasive f...

متن کامل

Fetal Electrocardiogram (fECG) Gated MRI

We have developed a Magnetic Resonance Imaging (MRI)-compatible system to enable gating of a scanner to the heartbeat of a foetus for cardiac, umbilical cord flow and other possible imaging applications. We performed radiofrequency safety testing prior to a fetal electrocardiogram (fECG) gated imaging study in pregnant volunteers (n = 3). A compact monitoring device with advanced software capab...

متن کامل

An Effective Technique for Enhancing an Intrauterine Catheter Fetal Electrocardiogram

Physicians can obtain fetal heart rate, electrophysiological information, and uterine contraction activity for determining fetal status from an intrauterine catheters electrocardiogram with the maternal electrocardiogram canceled. In addition, the intrauterine catheter would allow physicians to acquire fetal status with one noninvasive to the fetus biosensor as compared to invasive to the fetus...

متن کامل

Intrapartum fetal surveillance.

Intrapartum hypoxia was thought to contribute to the incidence of cerebral palsy, seizures and mental retardation. Electronic fetal monitoring was expected to prevent or reduce this incidence. Electronic fetal monitoring has a high false positive rate and fetal blood sampling, which is an invasive procedure, only allows an intermittent assessment. Efforts are being made to improve fetal heart r...

متن کامل

INTELLIGENT TECHNIQUE OF CANCELING MATERNAL ECG IN FECG EXTRACTION

In this paper, we propose a technique of artificial intelligence called adaptive neuro fuzzy inference system (ANFIS) for canceling maternal electrocardiogram (MECG) in fetal electrocardiogram extraction (FECG).This technique is used to estimate the MECG present in the abdominal signal of a pregnant woman. The FECG is then extracted by subtracting the estimated MECG from the abdominal signal. P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of perinatal medicine

دوره 14 6  شماره 

صفحات  -

تاریخ انتشار 1986