Background The aim of this study was to evaluate the oncological outcomes of hepatocellular carcinoma patients undergoing liver resection using cavitron ultrasonic surgical aspirator (CUSA) or radiofrequency (RF) based device Habib-4X.
. Study Design We prospectively analyzed the data of 280 patients who underwent liver resection for hepatocellular carcinoma at our institution from 2010-2012 with follow up till August 2016. The CUSA was used in the 163 patients whilst Habib-4X in 117 patients. The end points of analysis were oncological outcomes as disease recurrence, disease-free survival (DFS) and overall survival (OS) were estimated by the Kaplan-Meier method, which has been compared with all other existing literature on the survival study. Results Compared with CUSA the reported incidence of recurrence was significantly lower, in Habib-4X group; p < 0.01. The median DFS was significantly better in Habib-4X group than CUSA group (50.80 vs 45.87 months, p = 0.03). The median OS was better in Habib-4X group than CUSA group (60.57 vs 57.17 months, p = 0.12) though the lesser difference in OS between the groups might be explained by the use of palliative therapies as TACE, percutaneous RFA, etc. in case of recurrence. Conclusions RF based device Habib-4X, is safe and effective device for resection of hepatocellular carcinoma, in comparison to CUSA with better oncological outcomes, i.e., significantly lesser tumour recurrence and better DFS. This could be explained on the basis of systemic and local immunomodulatory effect involving induction of kupffer cells and effector CD-8 T cells that help in minimizing postoperative complications and bring more advantageous oncological outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of a clamp method combined with bipolar coagulation for anatomical hepatectomy in the treatment of hepatic carcinoma.

PURPOSE This study investigated the effectiveness of a clamp method combined with bipolar coagulation for anatomical hepatectomy in the treatment of hepatocellular carcinoma (HCC). METHODS In this prospective case-control study, three liver dissection methods were used: clamping combined with bipolar electric coagulation (group A), CUSA (Cavitron ultrasonic surgical aspirator) (group B), and ...

متن کامل

Two-surgeon technique using saline-linked electric cautery and ultrasonic surgical aspirator in living donor hepatectomy: its safety and efficacy.

BACKGROUND Saline-linked electric cautery (SLC) is introduced as an effective device to reduce blood loss in liver surgery. The aim of the current study was to evaluate the safety and efficacy of a 2-surgeon technique using SLC and the Cavitron Ultrasonic Surgical Aspirator (CUSA; Valleylab, Boulder, CO) in living donor hepatectomy. METHODS Forty-three living donor right hepatectomy cases wer...

متن کامل

Atypical hepatic resection technique for hepatocellular carcinoma using radiofrequency Habib™ 4X Device.

INTRODUCTION The number of liver resections significantly increased worldwide in the last 20 years. In many hepatic tumours, liver resection remains the best therapeutic option. A difficult intraoperative goal is to obtain a safe haemostasis on the transection plane. Technological innovation in recent decades allowed the development of different tools that allow better control of bleeding, fast...

متن کامل

Multiple cerebral infarction and paradoxical air embolism during hepatectomy using the Cavitron Ultrasonic Surgical Aspirator -A case report-

A venous air embolism and paradoxical air embolism (PAE) are serious complications in patients undergoing a hepatectomy. We report a case of PAE and cerebral infarctions in a patient undergoing a hepatic resection using a Cavitron Ultrasonic Surgical Aspirator (CUSA®). A 65-year-old woman underwent a left lobe hepatectomy. During the middle phase of the liver resection with CUSA®, there was a s...

متن کامل

Comparing PET metabolic parameters with clinicopathological factors in predicting onset of early recurrence in recently diagnosed hepatocellular carcinoma

Introduction: Early recurrence of hepatocellular carcinoma (HCC) is a major risk factor affecting survival even after hepatectomy. Many clinical, biochemical parameters and pathological grading like fibrosis 1 index have been used for risk stratifying HCC. However not many studies have combined all of them. It is therefore important to risk stratify HCC especially with newer PE...