Size-dependent scanning parameters (kVp and mAs) for photon-counting spectral CT system in pediatric imaging: simulation study.

نویسندگان

  • Han Chen
  • Mats Danielsson
  • Cheng Xu
چکیده

We are developing a photon-counting spectral CT detector with a small pixel size of [Formula: see text] mm(2), offering a potential advantage for better visualization of small structures in pediatric patients. The purpose of this study is to determine the patient size dependent scanning parameters (kVp and mAs) for pediatric CT in two imaging cases: adipose imaging and iodinated blood imaging. Cylindrical soft-tissue phantoms of diameters between 10-25 cm were used to mimic patients of different ages from 0 to 15 y. For adipose imaging, a 5 mm diameter adipose sphere was assumed as an imaging target, while in the case of iodinated imaging, an iodinated blood sphere of 1 mm in diameter was assumed. By applying the geometry of a commercial CT scanner (GE Lightspeed VCT), simulations were carried out to calculate the detectability index, [Formula: see text], with tube potentials varying from 40 to 140 kVp. The optimal kVp for each phantom in each imaging case was determined such that the dose-normalized detectability index, [Formula: see text]dose, is maximized. With the assumption that the detectability index in pediatric imaging is required the same as in typical adult imaging, the value of mAs at optimal kVp for each phantom was selected to achieve a reference detectability index that was obtained by scanning an adult phantom (30 cm in diameter) in a typical adult CT procedure (120 kVp and 200 mAs) using a modeled energy-integrating system. For adipose imaging, the optimal kVps are 50, 60, 80, and 120 kVp, respectively, for phantoms of 10, 15, 20, and 25 cm in diameter. The corresponding mAs values required to achieve the reference detectability index are only 9%, 23%, 24%, and 54% of the mAs that is used for adult patients at 120 kVp, for 10, 15, 20, and 25 cm diameter phantoms, respectively. In the case of iodinated imaging, a tube potential of 60 kVp was found optimal for all phantoms investigated, and the mAs values required to achieve the reference detectability index are 2%, 9%, 37%, and 109% of the adult mAs. The results also indicate that with the use of respective optimal kVps, the photon-counting spectral system offers up to 30% higher [Formula: see text]dose than the modeled energy-integrating system for adipose imaging, and 70% for iodinated imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization and Optimization of Silicon-strip Detectors for Mammography and Computed Tomography

The goal in medical x-ray imaging is to obtain the image quality required for a given detection task, while ensuring that the patient dose is kept as low as reasonably achievable. The two most common strategies for dose reduction are: optimizing incident x-ray beams and utilizing energy information of transmitted beams with new detector techniques (spectral imaging). In this thesis, dose optimi...

متن کامل

Optimization of beam quality for photon-counting spectral computed tomography in head imaging: simulation study.

Head computed tomography (CT) plays an important role in the comprehensive evaluation of acute stroke. Photon-counting spectral detectors, as promising candidates for use in the next generation of x-ray CT systems, allow for assigning more weight to low-energy x-rays that generally contain more contrast information. Most importantly, the spectral information can be utilized to decompose the ori...

متن کامل

Clinical Value of Low Dose CT- Scan in Pediatric Chest Diseases: Adequacy Assessment

Background Radiation dose about 400 times that of standard thoracic computed tomography (CT) in comparison with chest X- ray resulting in different approaches to decrease radiation dose have been established in the last few years to prevent possible side effects especially in children, such as low dose protocols. The aim of this study was assessment of clinical v...

متن کامل

Discrepancies in dose distributions due to age- dependent bone electron density in pediatric MRI-only treatment planning: A Monte Carlo study

Introduction: MRI-only treatment planning (TP) can be advantageous in paediatric radiotherapy. However, electron density extraction is necessary for dose calculation. Normally, after bone segmentation, a bulk density is assigned. However, the variation of bone bulk density in patients makes the creation of pseudo CTs challenging. This study aims to assess the effects of bone den...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 61 11  شماره 

صفحات  -

تاریخ انتشار 2016