The Effects of Subcutaneous Fat, Electrode Size and Inter-Electrode Distance During Transcutaneous Electrical Stimulation
نویسندگان
چکیده
Transcutaneous electrical stimulation is used as an adjunct therapy for obesity, where it can enable increased levels of voluntary exercise. Due to the high resistivity of subcutaneous fat tissue, however, high stimulus currents are required to evoke muscle contraction in obese subjects, possibly leading to patient discomfort. In this study, a three-dimensional finite element model of the human thigh, including skin, fat, muscle and bone, was developed to examine the effects of fat thickness, electrode size and inter-electrode distance on the level of evoked muscle activation, examined using the activating function, during monopolar and bipolar stimulation. The results indicate that increased electrode size may reduce patient discomfort while maintaining the efficacy of the electrical stimulation in obese patient populations. Additionally, muscle activation appeared to be less sensitive to inter-electrode distance as fat thickness increased.
منابع مشابه
Influence of Subcutaneous Fat Thickness upon the Activation Volume in Transcutaneous Electrical Stimulation to a Thigh Simulation Model
Activation Volume, which is calculated from the Activating Function, describes the spatial location of nerve activation, thus is useful in optimizing stimulation electrodes geometry and waveform for improving selectivity and comfort in transcutaneous electrical stimulation. For example, the discomfort due to the fat thickness has been studied before, but the effect of fat thickness on selectivi...
متن کاملDC electrical stimulation for chronic wound healing enhance1nent. Part 2. Parameter determination by numerical modelling
A three dimensional finite element model of the cut:meous wound stimulated by direct electric current was built by means of the finite element method, As was assumed in part I of this article, the endogenous electrical properties of the injured skin are' beneficial and necessary for a normal course of healing. Therefore, an attempt was made to determine the parameters of transcutaneous electric...
متن کاملA Selectivity Measure for Transcutaneous Electrodes
Transcutaneous electrical stimulation (TES) enables functional movements of human limbs by applying electrically generated pulses to pairs of electrodes placed on the skin surface. New TES technology uses multi-channel configurable electrodes that can dynamically distribute the stimulation current across the skin surface. Such systems require a quantitative understanding of the spatial and temp...
متن کاملAcoustic Analysis of Voice Change in Normal Speakers Following Transcutaneous Electrical Stimulation to the Laryngeal Area
Transcutaneous electrical stimulation (TES) is being used more frequently by speech-language pathologists to treat individuals with dysphagia since the advent of VitalStim ® . Anecdotal reports suggest changes in voice quality associated with TES. This study was completed to examine acoustic measures of voice change in normal speakers following TES. Thirty speakers with normal voices, ages 19-5...
متن کاملThe Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses
This study investigates the impact of the subcutaneous fat layer (SFL) thickness on localized electrical impedance myography (EIM), as well as the effects of different current electrodes, varying in distance and direction, on EIM output. Twenty-three healthy subjects underwent localized multi-frequency EIM on their biceps brachii muscles with a hand-held electrode array. The EIM measurements we...
متن کامل