Gas-sampling technique for arsenic determination by atomic absorption spectrophotometry.
نویسنده
چکیده
IN CONVENTIONAL atomic absorption spectrophotometry a solution of the sample is introduced into the flame as an aerosol by means of a nebulizer. However, commercial nebulizers are only about 5 efficient in forming fine droplets suitable for atomization by the flame ( I ) . Furthermore, a solution aspirated at a usual rate of 3-5 ml/min for about 10 sec produces a concentration signal extending over the length of aspiration. Theoretically, if the element were introduced into the flame rapidly-e.g., 1 second-with no loss, a high narrow signal should result and the detection limit should improve. Several devices aimed at improving the efficiency of atomic absorption sampling have been described in the literature. One scheme, developed by Brandenberger and Bader (2) was used to determine nanogram amounts of mercury. In their technique, mercury in solution was deposited on a copper wire and placed io the arm of a specially constructed cell with quartz windows. An electrical potential applied across the wire volatilized the mercury instantaneously. The mercury vapors were then swept through the cell with air and the atomic absorption signal was recorded as a function of time. The above “flameless” technique cannot be used to determine arsenic because of the high temperature required to maintain arsenic in its vapor state. Arsenic often needs to be determined in trace amounts, and an improvement in the present detectian limit of about 0.5 ppm would be desirable. This can be achieved if arsine is generated from the sample, collected in a cold trap such as liquid nitrogen, and then passed into the burner of an atomic absorption spectrophotometer, with the signal recorded cs. time.
منابع مشابه
Determination of arsenic(III) by flow injection solid phase extraction coupled with on-line hydride generation atomic absorption spectrometry using a PTFE turnings-packed micro-column.
A novel flow injection (FI) solid phase extraction method for the determination of arsenic(III) at trace levels was developed, using on-line hydride generation atomic absorption spectrometry (HG-AAS). Selective determination of As(III) was achieved by on-line formation and retention of the pyrrolidine dithiocarbamate arsenic complex As(III)-PDC on the PTFE turnings which are packed in the preco...
متن کاملArsenic speciation by hydride generation-Quartz furnace atomic absorption spectrometry. Optimization of analytical parameters and application to environmental samples
Analytical parameters of hydride generation, trapping, gas chromatography and atomic absorption spectrometry detection in a quartz cell furnace (HG/GC/QFAAS) device have been optimized in order to develop an efficient and sensitive method for arsenic compounds speciation. Good performances were obtained with absolute detection limits in the range of 0.1 – 0.5 ng for arsenite, arsenate, monometh...
متن کاملDetermination of arsenic(III) and total inorganic arsenic in water samples using an on-line sequential insertion system and hydride generation atomic absorption spectrometry
A simple and robust on-line sequential insertion system coupled with hydride generation atomic absorption spectrometry (HG-AAS) was developed, for selective As(III) and total inorganic arsenic determination without pre-reduction step. The proposed manifold, which is employing an integrated reaction chamber/gas–liquid separator (RC-GLS), is characterized by the ability of the successful managing...
متن کاملDevelopment of a Simple System for the Determination of Arsenic after Hydride Generation Atomic Absorption Spectrophotometry
Journal of Applied Sciences & Environmental Management, Vol. 5, No. 1, June, 2001, pp. 9-16 Development of a Simple System for the Determination of Arsenic after Hydride Generation Atomic Absorption Spectrophotometry * MUMUNI, A.R. ; PEACOCK, C. J Department of chemistry, University of Lancaster, Lancaster LAI 4YA, UK *Corresponding author Present address: Department of Pure and Industrial Chem...
متن کاملInterferences in the quartz tube atomizer during arsenic and antimony determination by hydride generation atomic absorption spectrometry
Interferences of some metals in the determination of arsenic by hydride generation atomic absorption spectrometry utilizing a quartz tube atomizer were studied. The atomizers were coated under vacuum with Ni, Au, Pd and Cr. The arsenic signal was almost totally suppressed by all the metal coatings and thus the interferences from metal ions in the determination of arsenic were attributed both to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 41 12 شماره
صفحات -
تاریخ انتشار 1969