Physiological flow analysis in significant human coronary artery stenoses.
نویسندگان
چکیده
To evaluate the local hemodynamics in flow limiting coronary lesions, computational hemodynamics was applied to a group of patients previously reported by Wilson et al. (1988) with representative pre-angioplasty stenosis geometry (minimal lesion size d(m)=0.95 mm; 68% mean diameter stenosis) and with measured values of coronary flow reserve (CFR) in the abnormal range (2.3+/-0.1). The computations were at mean flow rates (Q) of 50, 75 and 100 ml/min (the limit of our converged calculations). Computed mean pressure drops Deltap were approximately 9 mmHg for basal flow (50 ml/min), approximately 27 mmHg for elevated flow (100 ml/min) and increased to an extrapolated value of approximately 34 mmHg for hyperemic flow (115 ml/min), which led to a distal mean coronary pressure p(rh) of approximately 55 mmHg, a level known to cause ischemia in the subendocardium (Brown et al., 1984), and consistent with the occurrence of angina in the patients. Relatively high levels of wall shear stress were computed in the narrow throat region and ranged from about 600 to 1500 dyn/cm(2), with periodic (phase shifted) peak systolic values of about 3500 dyn/cm(2). In the distal vessel, the interaction between the separated shear layer wave, convected downstream by the core flow, and the wall shear layer flow, led to the formation of vortical flow cells along the distal vessel wall during the systolic phase where Reynolds numbers Re(e)(t) were higher. During the phasic vortical mode observed at both basal and elevated mean flow rates, wide variations in distal wall shear stress occurred, distal transmural pressures were depressed below throat levels, and pressure recovery was larger farther along the distal vessel. Along the constriction (convergent) and throat segments of the lesion the pulsatile flow field was principally quasi-steady before flow separation occurred. The flow regimes were complex in the narrow mean flow Reynolds number range Re(e)=100-230 and a frequency parameter of alphae=2.25. The shear layer flow disturbances diminished in strength due to viscous damping along the distal vessel at these relatively low values of Re(e), typical of flow through diseased epicardial coronary vessels. The distal hyperemic flow field was likely to be in an early stage of turbulent flow development during the peak systolic phase.
منابع مشابه
Identification of coronary artery stenoses and poststenotic blood flow patterns using a miniature high-frequency epicardial transducer.
BACKGROUND Intraoperative epicardial coronary Doppler ultrasound has the potential to provide anatomic and functional information. This technique has been hindered by the large size of standard transducers, but a miniature transducer is available that may fulfill the potential of coronary ultrasound. METHODS AND RESULTS Twenty consecutive patients who were undergoing coronary artery bypass gr...
متن کاملThe effect of turbulence model on predicting the development and progression of coronary artery atherosclerosis
A severe case of stenosis in coronary arteries results in turbulence in the blood flow which may lead to the formation or progression of atherosclerosis. This study investigated the turbulent blood flow in a coronary artery with rigid walls, as well as 80% single and double stenoses on blood flow. A finite element-based software package, ADINA 8.8, was employed to model the blood flow. The hemo...
متن کاملCoronary pressure and flow relationships in humans: phasic analysis of normal and pathological vessels and the implications for stenosis assessment: a report from the Iberian–Dutch–English (IDEAL) collaborators
BACKGROUND Our understanding of human coronary physiological behaviour is derived from animal models. We sought to describe physiological behaviour across a large collection of invasive pressure and flow velocity measurements, to provide a better understanding of the relationships between these physiological parameters and to evaluate the rationale for resting stenosis assessment. METHODS AND...
متن کامل“ Resistance in the cath lab ” : the utility of hyperemic stenosis resistance in the functional assessment of coronary artery disease
Percutaneous coronary intervention (PCI) guided by functional assessment of coronary stenoses, either noninvasively or invasively, by selective treatment of ischemia-inducing stenoses confers improved cardiovascular outcomes. We present the case of a 56-year-old man with multivessel coronary artery disease, who underwent PCI guided by invasive physiological assessment using both single modality...
متن کاملChange in coronary blood flow after percutaneous coronary intervention in relation to baseline lesion physiology: results of the JUSTIFY-PCI study.
BACKGROUND Percutaneous coronary intervention (PCI) aims to increase coronary blood flow by relieving epicardial obstruction. However, no study has objectively confirmed this and assessed changes in flow over different phases of the cardiac cycle. We quantified the change in resting and hyperemic flow velocity after PCI in stenoses defined physiologically by fractional flow reserve and other pa...
متن کاملStructural abnormalities of the coronary arterial wall--in addition to luminal narrowing--affect myocardial blood flow reserve.
UNLABELLED Multislice CT provides information on coronary luminal narrowing and on the structural abnormalities of the coronary arterial wall using densitometric analysis. We sought to investigate the effects of coronary luminal narrowing, structural abnormalities of the coronary arterial wall, and cardiovascular risk factors on regional and global myocardial blood flow (MBF) reserve. METHODS...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biorheology
دوره 40 4 شماره
صفحات -
تاریخ انتشار 2003