Sensitivity and specificity of concealed entrainment for the identification of a critical isthmus in the atrium: relationship to rate, anatomic location and antidromic penetration.

نویسندگان

  • Joseph B Morton
  • Prashanthan Sanders
  • Vincent Deen
  • Jithendra K Vohra
  • Jonathan M Kalman
چکیده

OBJECTIVES This study was designed to determine the sensitivity and specificity of concealed entrainment (CE) for the identification of a critical isthmus in the atrium. BACKGROUND Isthmus identification during entrainment mapping of macro-reentrant atrial tachycardia (MRAT) relies on the demonstration of CE. METHODS Using the model of typical atrial flutter, entrainment was performed in 10 patients at four rates (flutter cycle length [FCL] minus 10/20/30/40 ms) from seven sites: isthmus entrance/exit, low lateral/high lateral/high septal right atrium and proximal/distal coronary sinus. Surface 12-lead electrocardiogram fusion was evaluated by three observers blind to patient status. The extent of antidromic penetration (AP) was measured off the pacing catheter positioned around the tricuspid annulus. RESULTS The sensitivity for CE identifying any isthmus site was greatest at FCL-10 (100%), but the specificity was poor (54%). Conversely, specificity was greatest at FCL-40 (98%), but the sensitivity was poor (65%), with manifest entrainment (ME) observed from the isthmus entrance in 70% of episodes. At FCL-30, sensitivity (85%) and specificity (90%) were "balanced," but CE still resulted during entrainment from a non-isthmus site in five of 10 patients. Antidromic penetration increased with pacing CL shortening (p < 0.001) and correlated with the development of ME (p < 0.001). Antidromic penetration was significantly blunted from the isthmus exit compared to all other sites (p = 0.003). CONCLUSIONS The sensitivity and specificity of CE for identifying an isthmus in the atrium are critically dependent on the pacing rate and the precise anatomic pacing site within the isthmus. These findings may have implications for the use of entrainment in the mapping of unknown MRAT circuits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanisms of entrainment of human common flutter studied with multiple endocardial recordings.

BACKGROUND The mechanisms of common atrial flutter entrainment have not been directly studied in humans. METHODS AND RESULTS Endocardial mapping in six cases of common flutter showed large right atrial (RA) reentry circuits. Activation was craniocaudal in the anterolateral right atrium and caudocranial in the septum. The inferior vena cava-tricuspid isthmus (IVC-TV) closed the circuit. The hi...

متن کامل

Further observations on transient entrainment: importance of pacing site and properties of the components of the reentry circuit.

Transient entrainment of circus-movement tachycardia utilizing an atrioventricular (AV) bypass pathway was studied in 13 patients (nine with the orthodromic form, two with the antidromic form, and two with both the orthodromic and antidromic forms). All patients had a left-sided AV bypass pathway. Pacing at selected rates faster than the spontaneous rate was performed during the tachycardia at ...

متن کامل

CMR-based identification of critical isthmus sites of ischemic and nonischemic ventricular tachycardia.

OBJECTIVES This study evaluates whether contrast-enhanced (CE) cardiac magnetic resonance (CMR) can be used to identify critical isthmus sites for ventricular tachycardia (VT) in ischemic and nonischemic heart disease. BACKGROUND Fibrosis interspersed with viable myocytes may cause re-entrant VT. CE-CMR has the ability to accurately delineate fibrosis. METHODS Patients who underwent VT abla...

متن کامل

Anatomic Barrier in the Canine Atrium Observations During Entrainment and Termination

We determined total right atrial activation sequences during entrainment and termination of flutter induced in dogs with a surgically induced atrial lesion. This type of atrial flutter is due to circus movement of an impulse around the tricuspid valve orifice. We recorded simultaneously from 96 bipolar intracavity electrodes in the right atrium of the isolated, perfused heart. By constructing i...

متن کامل

Incidence, location, and type of isthmus in mandibular second molars among individuals of an Iranian population

BACKGROUND AND AIM: Isthmuses are narrow and strip shaped connections between two canals containing pulpal tissue that may encompass bacteria as well. They are hardly accessible for cleaning; therefore, success and failure of root canal treatments could be affected by their presence. The present study was carried out aiming to evaluate the incidence, location, and type of isthmus in mandibular ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 39 5  شماره 

صفحات  -

تاریخ انتشار 2002