Single sweep three-dimensional carotid ultrasound: reproducibility in plaque and artery volume measurements.

نویسندگان

  • Hayrapet Kalashyan
  • Ashfaq Shuaib
  • Patrick H Gibson
  • Helen Romanchuk
  • Maher Saqqur
  • Khurshid Khan
  • Jonathon Osborne
  • Harald Becher
چکیده

BACKGROUND There is a need for non-invasive and accurate techniques for assessment of severity of atherosclerotic disease in the carotid arteries. Recently an automated single sweep three-dimensional ultrasound (3D US) technique became available. The aims of this study were to evaluate the feasibility and reproducibility of the automated single sweep method in a cohort of patients undergoing clinically indicated carotid ultrasound. METHODS Consecutive patients with a history of stroke or transient ischemic attack (TIA) and having a plaque in the internal carotid artery (ICA) were recruited for this study. Imaging was performed using a Philips iU 22 ultrasound system equipped with the single sweep volumetric transducer vL 13-5. Analysis was performed offline with software provided by the manufacturer. Two independent observers performed all measurements. RESULTS Of 137 arteries studied (from 79 patients), plaque and artery volumes could be measured in 106 (77%). Reproducibility of plaque volume measurements was assessed in 82 arteries. Bland-Altman analysis demonstrated good inter-observer reproducibility with limits of agreement -0.06 to +0.07 ml. The mean percentage difference between two observers was 5.6% ± 6.0%. Reproducibility of artery volume measurement was assessed in 31 cases. Bland-Altman analysis demonstrated limits of agreement from -0.15 to +0.15 ml. The mean percentage difference was 6.4 ± 5.9%. CONCLUSION The new automated single sweep 3D ultrasound is feasible in the majority of patients. Good reproducibility in plaque and artery volume measurements makes this technique suitable for serial assessment of carotid plaques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrafast three-dimensional ultrasound: application to carotid artery imaging.

BACKGROUND AND PURPOSE Three-dimensional (3-D) vascular ultrasound can be expected to improve qualitative evaluation of vessel pathology and to provide quantitative data on vascular morphology and function. The objective of this study was to develop an ultrafast 3-D vascular system and to validate its performance for quantitation of atherosclerosis and assessment of regional arterial distensibi...

متن کامل

Interstudy reproducibility of three-dimensional volume-selective fast spin echo magnetic resonance for quantifying carotid artery wall volume.

PURPOSE To assess the interstudy reproducibility of a three-dimensional volume-selective, fast spin echo (FSE) magnetic resonance technique for the assessment of carotid artery wall volume, which is a marker for total carotid plaque volume. MATERIALS AND METHODS Interstudy reproducibility was evaluated in 10 subjects with evidence of carotid artery atherosclerotic disease on carotid Doppler u...

متن کامل

Three-dimensional ultrasound study of carotid arteries before and after endarterectomy; analysis of stenotic lesions and surgical impact on the vessel.

BACKGROUND AND PURPOSE It has been proved that symptomatic patients with severe carotid stenosis benefit from endarterectomy. Currently used methods for quantitation of the severity of carotid stenosis have limitations, and the impact of endarterectomy on the operated region of carotid artery remains unknown. The purpose of this study was to examine the accuracy of a 3-D ultrasound system for q...

متن کامل

Observer performance in characterization of carotid plaque texture and surface characteristics with 3D versus 2D ultrasound

OBJECTIVE To determine the reproducibility of three-dimensional (3D) ultrasound (US) over two-dimensional (2D) US in characterizing atherosclerotic carotid plaques using inter- and intra-observer agreement metrics. METHODS A Total of 51 patients with 105 carotid artery plaques were screened using 3D and 2D US probes attached to the same US scanner. Two independent observers characterized the ...

متن کامل

Automatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images

Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Atherosclerosis

دوره 232 2  شماره 

صفحات  -