Predictors of non-diagnostic cytology in surgeon-performed ultrasound guided fine needle aspiration of thyroid nodules
نویسندگان
چکیده
BACKGROUND Fine needle aspiration (FNA) is the standard of care for the diagnostic work-up of thyroid nodules but despite its proven utility, the non-diagnostic rate for thyroid FNA ranges from 6-36%. A non-diagnostic FNA is problematic for the clinician and patient because it can result in repeated procedures, multiple physician visits, and a delay in definitive treatment. Surgeon-performed FNA has been shown to be safe, cost-effective, as accurate as those performed by other clinicians, and has the added benefit of decreasing wait times to surgery. Several studies have examined rates and factors that may be predictive of a non-diagnostic cytology in non-surgeon FNA, but none have evaluated this in surgeon-performed thyroid FNA. If these factors are unique in surgeon-performed vs. non-surgeon performed thyroid FNA, then patients may be more appropriately triaged to FNA by alternate clinicians. OBJECTIVES The purpose of this study was to determine the rate and factors predictive of a non-diagnostic FNA in surgeon performed ultrasound-guided FNA of thyroid nodules. METHODS We conducted a retrospective review of all adult patients who underwent thyroid FNA by a staff, fellow, or resident Otolaryngologist at the University of Alberta between January 2011 and June 2013. Factors analyzed included patient factors, thyroid characteristics, nodule characteristics, and surgeon level of training and experience. Univariate and multivariate binary logistic regression analysis were performed. RESULTS 131 patients (180 nodules) were reviewed. The non-diagnostic rate was 23%. Nodules with predominant cystic component, those less than 1 cm, and resident-performed FNA were associated with non-diagnostic cytology (p = 0.001, p = 0.02, p = 0.04 respectively). A cystic nodule was the only independent predictor of non-diagnostic FNA on multivariate analysis (OR = 4.441, 95% CI [1.785-11.045], p = 0.001). CONCLUSIONS The rate of non-diagnostic thyroid FNA performed by a surgeon with ultrasound guidance is similar to other clinicians. A cystic nodule is a strong independent predictor of non-diagnostic cytology. Non-cystic nodules may particularly benefit from surgeon-performed thyroid FNA due to the high diagnostic rate and potential for earlier definitive management.
منابع مشابه
Senthil P et al ACCURACY OF ULTRASOUND GUIDED FINE NEEDLE ASPIRATION CYTOLOGY IN THE EVALUATION OF THYROID NODULES
Background: Thyroid nodules are a common problem which requires an accurate cytological diagnosis for proper management. An essential investigation modality is fine needle aspiration cytology (FNAC) with a sensitivity ranging between 80-90%. Recommendations vary regarding the use of ultrasound in improving the accuracy of free hand fine needle aspiration biopsy. Objective: The aim of our study ...
متن کاملRole of Fine Needle Aspiration Cytology in Diagnosis of Solitary Thyroid Nodules
Introduction: This study was conducted at the Department of ear, nose, throat, head and neck surgery, Post Graduate Medical Institute Lady Reading Hospital Peshawar. The duration of the study was one year from June 17, 2009 to June 16, 2010. The sample size was 82 patients with solitary thyroid nodule, fulfilling the inclusion criteria. After taking detailed history, thorough examination, rele...
متن کاملComparision of the Diagnostic values of Doppler Sonography with Fine Needle Aspiration in Thyroid Nodules
Introduction: Thyroid nodules are frequent occurrences, and whenever diagnosed, it is necessary to rule out of malignancy. Valuable diagnostic methods in this field are sonography and fine needle aspiration. In this study while investigating these two methods, we compared them with postsurgical pathologic findings. Materials and methods: This is a cross sectional, descriptive-analytical study. ...
متن کاملProper Indication of BRAFV600E Mutation Testing in Fine-Needle Aspirates of Thyroid Nodules
BACKGROUND The aim of this study was to evaluate the proper indication of adjunctive BRAF(V600E) mutation analysis at the time of ultrasound-guided fine-needle aspiration in the diagnosis of thyroid nodules. METHODS This study included 518 nodules in 479 patients who underwent ultrasound-guided fine-needle aspiration with BRAF(V600E) mutation. We calculated and compared the diagnostic perform...
متن کاملComparison of Cytologic Reports of Fine-Needle Aspiration of Thyroid Nodules with Pathologic Results of Thyroid Surgery
Background and Objective: Thyroid nodules are among the most common clinical problems and the application of an inexpensive and accurate diagnostic method prevents performing inessential surgeries. In this regard, the aim of this study was to compare the cytologic report of fine-needle aspiration (FNA) of thyroid nodules with the results of thyroid surgery. Materials and Methods: In this cross...
متن کامل