On-chip microdialysis system with flow-through glucose sensing capabilities.
نویسندگان
چکیده
BACKGROUND Microdialysis is a sampling technique based on controlling the mass transfer rate of different-sized molecules across a semipermeable membrane. Because the dialysis process has minimal effects on the surrounding fluid, it is viewed as a tool for continuous monitoring of human metabolites. In diabetes treatment, microdialysis probes have been used as sampling systems coupled to a glucose biosensor but may struggle to obtain high recoveries of analytes, as the sampling housing, probes, and glucose sensors are fabricated as separate pieces and then assembled, resulting in a large dead volume, which limits sensing frequency. An in situ combination of a miniaturized microdialysis probe with an integrated glucose sensor could help solve some of these problems. METHOD The system was fabricated by bonding a 6-mum-thick polycarbonate track-etch membrane with 100-nm-diameter pores onto microfluidic channels with the electrochemical glucose sensing electrodes patterned within the microchannels. RESULTS In vitro experiments demonstrating glucose microdialysis with continuous sensing were conducted. The permeability of glucose to the polycarbonate membrane with a 100-nm-diameter pore size was obtained to be 5.44 mum/s. Glucose recovery of 99% was observed using this microdialysis system at a perfusion flow rate of 0.5 microl/min. Experiments monitoring fluctuating glucose concentrations in the time domain at 99% recovery were also performed. The lag time was measured to be 210 seconds with 45 seconds contributed by mass transfer limitations and the rest from dead volume within the experimental setup. CONCLUSION The electrochemical sensing component was able to continuously track concentration changes in the reservoir. This system is expected to have the proper sensitivity to track physiologically relevant concentration changes of glucose with a lag time of less than 1 minute and minimal amplitude reduction for continuous glucose monitoring for diabetes treatment.
منابع مشابه
An amperometric on-chip glucose biosensor based on enzyme entrapment with pre-reaction to lower interference in a flow injection system
In this study, the flow injection analysis was applied to the enzyme-entrapped electrode on a chip for sensing glucose. The on-chip microelectrode was fabricated by the standard photolithography in clean-room environment and the microfluidic channel height of 100 μm on the chip was formed by poly(dimethylsiloxane). The conducting polymer, poly(3,4-ethylenedioxythiophene), PEDOT, was electropoly...
متن کاملSimultaneous determination of glucose and L-lactate in rat brain by an electrochemical in vivo flow-injection system with an on-line microdialysis sampling.
An electrochemical in vivo flow-injection system with an on-line microdialysis sampling is proposed for the simultaneous monitoring of L-lactate and glucose in rat brain. In the first stage of the operation, the dialysate from the microdialysis probe is delivered to a sample loop of the six-way autoinjector by perfusing Ringer's solution for 80 s at 5 microl min(-1). In the second stage, the di...
متن کاملDroplet-based micro-flow chemiluminescence system for in vivo glucose determination by microdialysis sampling.
A micro-flow chemiluminescence (CL) system in vivo for glucose determination by the on-line microdialysis sampling is described in this paper. The micro-flow CL system uses discrete sample droplets, which formed at the tip of the capillary with the sampling volume of 4.5 microl. The sol-gel method is introduced to co-immobilize horseradish peroxidase (HRP) and glucose oxidase (GOD) on the insid...
متن کاملSimultaneous monitoring of potassium, glucose and lactate during spreading depolarization in the injured human brain – Proof of principle of a novel real-time neurochemical analysis system, continuous online microdialysis
Spreading depolarizations occur spontaneously and frequently in injured human brain. They propagate slowly through injured tissue often cycling around a local area of damage. Tissue recovery after an spreading depolarization requires greatly augmented energy utilisation to normalise ionic gradients from a virtually complete loss of membrane potential. In the injured brain, this is difficult bec...
متن کاملMethod of Calibration of Glucose Sensor Implemented in an Integrated Microdialysis Based System
In this paper the novel method of calibration of glucose amperometric type sensor implemented in an integrated microdialysis based micro system is presented. This method consists in evaluation of the charge, resulting from the glucose consumption in the enzymatic reaction, transferred to the electrode under stop-flow conditions.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of diabetes science and technology
دوره 1 3 شماره
صفحات -
تاریخ انتشار 2007