Accuracy assessment of measuring component position after total ankle arthroplasty using a conventional method

نویسندگان

  • Kyoung-Jai Lee
  • Shao-Hua Wang
  • Gun-Woo Lee
  • Keun-Bae Lee
چکیده

BACKGROUND This study was to assess the accuracy of measuring the tibial and talar components position and to investigate the outlier rate of each component and predisposing factors related to component malalignment after total ankle arthroplasty (TAA) using a conventional method. METHODS One hundred fifty consecutive primary total ankle arthroplasty were performed using the three-component HINTEGRA prosthesis for ankle end-stage osteoarthritis. Radiographic analysis for the accuracy of component position in coronal and sagittal plane was conducted at postoperative 6 months. Additionally, the accuracy of component position was evaluated according to presence of preoperative deformity or joint incongruency. RESULTS The mean postoperative coronal angles of the tibial and talar components (α and γ) were 91.9° and 91.3°. The mean postoperative sagittal angles of the tibial and talar components (β and δ angle) were 84.6° and 91.7°. In the coronal plane, 16 (10.7%) tibial components and 15 (10.0%) talar components showed outliers greater than 5°. In sagittal plane, 15 (10.0%) tibial components and 29 (19.3%) talar components showed outliers greater than 5°. There was no meaningful increase of the outlier rate regarding presence of preoperative deformity or joint incongruency. CONCLUSIONS In conventional method of TAA, the outlier rate of the tibial and talar components was about 10 to 20%, especially, the outlier rate of talar component in sagittal plane was up to 20%. Therefore, careful attention should be paid to implant the talar component in conventional TAA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

Robot-assisted implantation improves the precision of component position in minimally invasive TKA.

Minimally invasive and robot-assisted procedures have potential advantages when used for total knee arthroplasty (TKA). The purpose of this cadaveric study was to examine whether robot-assisted minimally invasive procedures improve TKA alignment after modifying the robotic techniques and instruments. Total knee arthroplasties were performed on 10 pairs of fresh cadaveric femora. Ten knees were ...

متن کامل

Effect of anterior translation of the talus on outcomes of three-component total ankle arthroplasty

BACKGROUND Ankle osteoarthritis commonly involves sagittal malalignment with anterior translation of the talus relative to the tibia. Total ankle arthroplasty has become an increasingly popular treatment for patients with symptomatic ankle osteoarthritis. However, no comprehensive study has been conducted on the outcomes of total ankle arthroplasty for osteoarthritis with preoperative sagittal ...

متن کامل

The outcomes of cementless total ankle arthroplasty - pilot study.

BACKGROUND Since new generation ankle endoprostheses came into common use, total ankle arthroplasty has become an alternative to arthrodesis in the treatment of advanced osteoarthritis. The aim of paper was present preliminary results of cementless total ankle arthroplasty in patients with osteoarthritis. MATERIAL AND METHODS In 2012-2014, 12 cementless total arthroplasties of the ankle joint...

متن کامل

The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty

Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017