Dosimetric Conformity of Cobalt-60 (Co) Beams

نویسندگان

  • Sajjad Ahmed Memon
  • Naeem Ahmed Laghari
  • Fayaz Hussain Mangi
  • Ali Jafri
  • Muhammad Raza
  • Muhammad Ameen Abbasi
چکیده

Objective: The radiation dosimetry is the output measurement of radiation generating source/ machine and its ambition is to ensure that the teletherapy units’ outputs are within limits. In the current article, the dosimetry of Cobalt-60 (Co 60 ) teletherapy units at Nuclear Institute of Medicine and Radiotherapy (NIMRA), Jamshoro Pakistan was studied. As Co 60 is undergo decay process, the output (dose rate) also decreases, therefore regular output measurement is obligatory to deliver appropriate dose to patient. The over dosage leads to hazards of radiation and under dosage may cause inadequate cancer treatment. This study highlights constancy between actual output and output acquired using decay method. Material and Methods: In the present study, the evaluation and comparison in the measurement of actual dose rate and expected output using decay method of Co60 teletherapy units has been done. Results: The evaluation and comparison of the values of output obtained by the two methods (actual and the expected outputs by decay method) shows constancy. Most of the values obtained by actual dosimetry are within ±2% of the expected measurements. Conclusions: The variation in measurements obtained by two methods is within the tolerable limits according to standard protocols and codes. Thus our study shows a homogenous trend in dose rate and a better patient dose delivery to avoid over or under dosage. Keywords-Radiotherapy, Medium, Ionization Chamber, Cobalt-60 (Co 60 ), Dosimetry, Output, Dosimetric Constancy, Radioisotope

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Comparison of Various Radiotherapeutic Treatment Plans Using Cobalt-60 and Linac for Prostate Cancer

Introduction: This study was designed to evaluate dosimetric parameters such as rectal dose, bladder dose, integral dose (ID), homogeneity index (HI) and conformity index (CI) in various treatment plans for prostate cancer. Materials and Methods: Pelvic computed tomography (CT) scans of 27 patients were acquired and transferred to the RTDosePLAN treatment planning system. For each patient, 8 co...

متن کامل

Dosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies

Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...

متن کامل

An analysis of the regulatory program of quality audits in radiotherapy in Brazil from 1995 to 2007

The Brazilian Institute of Radiation Protection and Dosimetry (IRD/CNEN) carried out quality assurance regulatory audits in Brazilian radiotherapy facilities from 1995 to 2007. In this work, the set of data collected from 195 radiotherapy facilities that use high-energy photon beams are analyzed. They include results from audits in linear electron accelerators and/or Co-60 units. The inspectors...

متن کامل

Comparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)

Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients.   Materials and Methods: Co...

متن کامل

Dosimetric Consistency of Co-60 Teletherapy Unit- a ten years Study.

OBJECTIVE The goal of the Radiation standards and Dosimetry is to ensure that the output of the Teletherapy Unit is within ±2% of the stated one and the output of the treatment dose calculation methods are within ±5%. In the present paper, we studied the dosimetry of Cobalt-60 (Co-60) Teletherapy unit at Sher-I-Kashmir Institute of Medical Sciences (SKIMS) for last 10 years. Radioactivity is th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017