Perioperative Nursing Management of an Animal Model of Axial Flow Blood Pump Implantation

نویسندگان

  • Aimei Kang
  • Jinjun Li
  • Yong Zhou
  • Liu Hu
  • Zhengying Qiu
  • Xin Zhou
چکیده

Objective: This study aimed to explore the characteristics of perioperative nursing of experimental goats using self-made axial-flow blood pump implantation and provided theoretical nursing knowledge and practice-based evidence for the clinical application of domestically manufactured artificial cardiac pumps. Methods: Seven experimental goats were used in this study, three for pre-testing and four for the formal experiments. According to the surgical requirements for axial-flow blood pump implantation into the cardiac apex, we creatively designed and made a series of highly practical animal surgical instruments including a composite disassemblable bed for experimental animal transferring and monitoring, a multifunctional animal surgery bed, and portable medical supporting equipment. We also applied for two national invention patents and one utility model patent. Active measures were taken to ensure careful preparation before surgery, close collaboration during surgery, and effective management of complications after surgery. Results: Two of the four experimental goats died during surgery because of a massive hemorrhage caused by distal anastomotic failure and air embolism-induced cardiac arrest caused by air leakage from the outlet into the heart due to poor connection of the auxiliary pressure tap (used to measure left ventricular pressure). The mean survival time of the remaining three experimental goats was 22.7 hours. Conclusion: This study was the first to systematically and comprehensively investigate the perioperative nursing management of axial-flow blood pump implantation using animal models. These findings could greatly promote further clinical applied nursing research of self-made artificial cardiac pump implantation in experimental goats. Joint first author. Corresponding author.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Management of patients treated with left ventricular assist devices

This thesis describes the management of patients treated with mechanical circulatory support devices for shortor long-term use. Twenty-four patients suffering from postcardiotomy heart failure were treated with a minimally invasive axial flow pump. The device was effective in unloading the failing left ventricle and in maintaining an adequate systemic circulation. The principles of perioperativ...

متن کامل

Advances in Heart Failure Mechanisms of Bleeding and Approach to Patients With Axial-Flow Left Ventricular Assist Devices

During the past several decades, left ventricular assist devices (LVADs) have become a valuable therapeutic option in the management of advanced systolic heart failure. Durable LVADs are being used to provide long-term mechanical circulatory support to a growing population of patients with end-stage systolic heart failure refractory to medical and electric therapies. This advanced stage of hear...

متن کامل

Hemorrhage and thrombosis with different LVAD technologies: a matter of flow?

BACKGROUND Much of the morbidity and mortality associated with ventricular assist devices (VADs) is due to haemorrhagic and thrombotic complications. To manage antithrombotic therapy, interactions between the patient and pump should be better understood. METHODS We have compared the Jarvik 2000, an axial flow left ventricular assist device (LVAD), with the HeartWare ventricular assist device ...

متن کامل

First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation.

BACKGROUND A shortage of donor organs and increased numbers of deaths of patients on the waiting list for cardiac transplantation make mechanical circulatory support for a bridge to transplantation a standard clinical procedure. Continuous-flow rotary blood pumps offer exciting new perspectives. METHODS AND RESULTS Two male patients (ages 44 and 65 years) suffering from end-stage left heart f...

متن کامل

Unique ECG finding in a patient with an axial blood flow pump..

After implanting a permanent Jarvik 2000 Heart (Jarvik Heart, Inc) in a patient with end-stage heart failure (Figure 1), we simultaneously recorded ECG and Doppler flow velocity in the vascular graft that connects the blood pump and descending aorta. With the pump temporarily switched off, the graft blood flow reversed, passing from the descending aorta through the device to the left ventricle....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016