An expandable percutaneous catheter pump for left ventricular support: proof of concept.

نویسندگان

  • Thomas Schmitz-Rode
  • Jürgen Graf
  • Joachim G Pfeffer
  • Frank Buss
  • Christoph Brücker
  • Rolf W Günther
چکیده

OBJECTIVES We sought to evaluate the performance of a newly designed percutaneous catheter with expandable pump. BACKGROUND The device was designed as a percutaneously insertable temporary support system for patients with acute left ventricular failure. METHODS The pump catheter (introduction diameter 9-F) is positioned in the left ventricle. The rotor is driven by an external motor through a flexible drive shaft. A model circuit was used to assess pump performance, hemolysis tests, and particle image velocimetry. The feasibility of the catheter placement and pump operation were examined in 12 anesthetized sheep. Cardiogenic shock was induced in seven of the animals. Cardiac output (CO) and mean aortic blood pressure (MAP) were recorded before and during shock, and during catheter pump action. RESULTS The catheter pump delivered a flow of 4.1 l/min at a differential pressure of 60 mm Hg. The average modified index of hemolysis was 11.6 (optimum, 1.8). Fluoroscopically and echocardiographically guided in vivo placement and deployment of the device were quick and uncomplicated. Under simulation of acute left ventricular failure (CO 43 +/- 22% and MAP 55 +/- 16% of the baseline value), the catheter pump significantly improved CO to 67 +/- 12% and MAP to 74 +/- 18%. Maximum in vivo duration of operation was 6 h (average, 3.1 +/- 1.4 h). These animal studies revealed: 1) no significant hemolysis (average plasma-free hemoglobin 26 +/- 4 mg/l after 3 h); 2) no thrombotic deposits at rotor or pump housing; and 3) no damage to the endocardium or aortic valve. CONCLUSIONS A percutaneously insertable, expandable catheter pump is technically and clinically feasible. Our first experimental results are encouraging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Initial experience: The use of novel balloon expandable sheaths with the impella 2.5L catheter during high risk percutaneous coronary intervention

Background: Vascular access remains a challenge in many patients who require ventricular support using the Impella catheter (Abiomed, Inc., Danvers, MA) for high risk percutaneous coronary intervention (PCI). Specifically, limitations of vessel size, calcification and tortuosity may make large bore access difficult. Balloon expandable (BE) sheath technology allows for the insertion of a smaller...

متن کامل

The PUCA pump: a left ventricular assist device.

Left ventricular assist devices (LVADs) that are being used clinically still have specific drawbacks. Therefore, a new concept for mechanical circulatory support was developed, the pulsatile catheter (PUCA) pump. It consists of an extracorporeally placed, pneumatically driven membrane pump that is connected to a valved catheter. The catheter is introduced into an easily accessible artery and po...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Successful percutaneous trans-catheter treatment of left ventricular assist device outflow graft stenosis with a covered stent

Left ventricular assist devices improve survival in patients with advanced heart failure but can be associated with significant complication including infection, pump thrombosis, and de novo severe aortic insufficiency. Outflow graft stenosis is a much more rare complication, but one with significant hemodynamic consequences. Surgical repair is often necessary, but many patients are too high ri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 45 11  شماره 

صفحات  -

تاریخ انتشار 2005