Feasibility Study of Air Conditioning System With Separated Dehumidification Process Using Low Temperature Exhaust Heat of Ice Storage

نویسنده

  • S. Nakabayashi
چکیده

The aim of this study is to develop an advanced air conditioning system. The dehumidification process of this system is separated from the cooling process and combined with an ice storage system. We use Wakkanai siliceous shale as a desiccant material. This is a natural mesoporous material produced in the northern area of Hokkaido, Japan. A honeycombed desiccant material made of the shale is cheaper than the one with silica-gel, and it can release vapor easily even by using low-temperature air. It was found that the desiccant process by using the shale honeycomb enables the temperature of regeneration to decrease to 40oC, whereas the desiccant process using silica-gel needs the temperature of 80oC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Peak Shifting and Energy Saving Potential of Ice Storage Based Air Conditioning Systems in Iran

Thermal energy storage (TES) system has been introduced as a practical facility for shifting load from peak hours to off-peak hours. Because of different energy consumption during day and night, peak and off peak period is created on load curve. Ice storage technology which is a kind of TES system, is implemented in different points of the world with the purpose of solving load shifting problem...

متن کامل

Theoretical and Experimental Analysis of Desiccant Air Conditioning System for Storage of Agricultural Products

The study emphasizes on the use of desiccant air conditioning (DAC) system for the storage of agricultural products. The chilling sensitivity of the tropical fruits and vegetables makes this system more promising for their optimal storage. The desiccant air conditioning system assisted by Maisotsenko cycle evaporative cooler is proposed in the study to achieve the latent and sensible load of ai...

متن کامل

Development of a Pilot Plant Solar Liquid Desiccant Air Conditioner for the Northern Region of Iran

In a 10-ton capacity pilot plant solar liquid desiccant air conditioner (LDAC) developed, dehumidification of the outside air is achieved through a honeycomb packed-bed heat and mass exchanger, using lithium chloride solution as the desiccant. The dry air obtained from the dehumidification process is evaporative cooled inside a cooling pad and directed into the conditioned space. The dilute sol...

متن کامل

An investigation of heat and mass transfer enhancement of air dehumidification with addition of γ-Al2O3 nano-particles to liquid desiccant

This study introduces an experimental and theoretical investigation of the performance of a proposed air dehumidification system using a nanofluid of γ-alumina nano-particles in LiBr/H2O as a desiccant. Comparative experiments organized using a central composite design were carried out to evaluate the effects of six numerical factors (air velocity, desiccant flow rate, air humidity ratio, desic...

متن کامل

Exergy Analysis of an Air Dehumidification System Equipped with Mixing Box and Heat Exchanger Heat Recovery Units

Exergy analysis emboldens in cases that all the inefficiencies and bottlenecks to improve energy systems are to be addressed. In this study, a novel vapor compression air dehumidifier integrated with an auxiliary heat exchanger in series arrangement with the main condenser in order to mitigate the reheat coil, and an extra mixing box to recover the ventilated air heat has been introduced. A com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009