The impact of trans-catheter aortic valve replacement induced left-bundle branch block on cardiac reverse remodeling

نویسندگان

  • Laura E. Dobson
  • Tarique A. Musa
  • Akhlaque Uddin
  • Timothy A. Fairbairn
  • Owen J. Bebb
  • Peter P. Swoboda
  • Philip Haaf
  • James Foley
  • Pankaj Garg
  • Graham J. Fent
  • Christopher J. Malkin
  • Daniel J. Blackman
  • Sven Plein
  • John P. Greenwood
چکیده

BACKGROUND Left bundle branch block (LBBB) is common following trans-catheter aortic valve replacement (TAVR) and has been linked to increased mortality, although whether this is related to less favourable cardiac reverse remodeling is unclear. The aim of the study was to investigate the impact of TAVR induced LBBB on cardiac reverse remodeling. METHODS 48 patients undergoing TAVR for severe aortic stenosis were evaluated. 24 patients with new LBBB (LBBB-T) following TAVR were matched with 24 patients with a narrow post-procedure QRS (nQRS). Patients underwent cardiovascular magnetic resonance (CMR) prior to and 6 m post-TAVR. Measured cardiac reverse remodeling parameters included left ventricular (LV) size, ejection fraction (LVEF) and global longitudinal strain (GLS). Inter- and intra-ventricular dyssynchrony were determined using time to peak radial strain derived from CMR Feature Tracking. RESULTS In the LBBB-T group there was an increase in QRS duration from 96 ± 14 to 151 ± 12 ms (P < 0.001) leading to inter- and intra-ventricular dyssynchrony (inter: LBBB-T 130 ± 73 vs nQRS 23 ± 86 ms, p < 0.001; intra: LBBB-T 118 ± 103 vs. nQRS 13 ± 106 ms, p = 0.001). Change in indexed LV end-systolic volume (LVESVi), LVEF and GLS was significantly different between the two groups (LVESVi: nQRS -7.9 ± 14.0 vs. LBBB-T -0.6 ± 10.2 ml/m2, p = 0.02, LVEF: nQRS +4.6 ± 7.8 vs LBBB-T -2.1 ± 6.9%, p = 0.002; GLS: nQRS -2.1 ± 3.6 vs. LBBB-T +0.2 ± 3.2%, p = 0.024). There was a significant correlation between change in QRS and change in LVEF (r = -0.434, p = 0.002) and between change in QRS and change in GLS (r = 0.462, p = 0.001). Post-procedure QRS duration was an independent predictor of change in LVEF and GLS at 6 months. CONCLUSION TAVR-induced LBBB is associated with less favourable cardiac reverse remodeling at medium term follow up. In view of this, every effort should be made to prevent TAVR-induced LBBB, especially as TAVR is now being extended to a younger, lower risk population.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complete atrioventricular block induced during left heart catheterization.

Complete atrioventricular block (CAVB) during cardiac catheterization is a rare complication. We describe a patient with preexisting complete right bundle branch block who developed CAVB during left-sided cardiac catheterization. CAVB was induced when a left-sided catheter was passed through the aortic valve. We speculate that the patient's His bundle was injured by mechanical compression. Phys...

متن کامل

Impact of New-Onset Left Bundle Branch Block and Periprocedural Permanent Pacemaker Implantation on Clinical Outcomes in Patients Undergoing Transcatheter Aortic Valve Replacement

Transcatheter aortic valve replacement (TAVR) is now an established treatment option for patients with aortic stenosis who are considered to be at high or prohibitive surgical risk. Substantial improvements in technology, patient selection, and refined procedural techniques have provided the basis for TAVRs expansion toward treating a lower surgical risk aortic stenosis population. However, the...

متن کامل

Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis.

AIMS New-onset left bundle branch block (LBBB) and complete atrioventricular block (AV3B) frequently occur following transcatheter aortic valve implantation (TAVI). We sought to determine the timing and potential mechanisms of new conduction abnormalities (CAs) during TAVI, using the Medtronic CoreValve System (MCS). METHODS AND RESULTS Sixty-five consecutive patients underwent TAVI with cont...

متن کامل

A Case of Transient Advanced Atrioventricular Block after Aortic Valve Replacement, Report of a Case

Approximately 3% 11.8% of cases require permanent pacemaker implantation due to atrioventricular block (AVB) after aortic valve replacement (AVR), and determination of conduction disturbances such as left or right bundle branch block by preoperative electrocardiography is correlated with high risk postoperative permanent pacemaker implantation. Intraoperative risk factors include severe calcifi...

متن کامل

Wide-QRS tachycardia immediately after aortic valve replacement.

A 49-year-old man with morbid obesity (6′5′′, 360 lbs), diabetes mellitus, hypercholesterolemia, and a history of systemic arterial hypertension had an aortic valve replacement for severe stenosis (aortic valve area, 0.9 cm2) with exertional dyspnea and left ventricular hypertrophy on echocardiogram. Immediately after operation an electrocardiogram was recorded (Figure 1). The electrocardiogram...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2017