Derivation of Expected Registration Error for Point-based Rigid-body Registration
نویسندگان
چکیده
This paper presents two new expressions for estimating registration accuracy in point-based rigid-body registration and points out a danger in using the traditional measure of registration accuracy. Rigid-body registration is appropriate for applications in which relatively rigid parts of the body are involved. In some such applications rigid-body registration is accomplished by aligning two sets of discrete points. In neurosurgical guidance, for example, the points are found by localizing the centroids of fiducial markers. This paper provides two new fundamental theoretical results on the relationship between localization error and registration error in rigidbody, point-based registration. Rigid-body, point-based registration is accomplished by finding a rigid-body transformation that aligns pairs of homologous "fiducial" points. The imprecision in locating a fiducial point is known as the "fiducial localization error" (FLE). Fiducial points may be centroids of attached markers, which tend to have small, equal FLEs, or salient points in segmented anatomic features, whose FLEs tend to be larger and more varied. Alignment is achieved by minimizing the "fiducial registration error" (FRE) , which is the root mean square distance between homologous fiducials after registration. Closed form solutions for the rigid transformation that minimizes FRE have been known since 1966. The expected value (FRE2) depends on the number N of fiducials and expected squared value of their fiducial localization error (FLE2), but in 1979 it was shown that (FRE2) is approximately independent of the fiducial configuration C. The importance of this surprising result seems not yet to have been appreciated by the registration community: Poor registrations caused by poor fiducial configurations may appear to be good. A more critical and direct measure of registration error is the "target registration error" (TRE) ,which is the distance between homologous points other than the centroids of fiducials. Efforts to characterize its behavior have been made since 1993 or earlier; published simulations have shown that (TRE2) is roughly proportional to (FLE2)/N and, unlike K FRE2), does depend in some way on C. In this work we present two major results: we first derive an approximate expression for (TRE2), and we then use this to calculate the expected squared alignment error for individual fiducials. This leads to a surprising conclusion the registration accuracy is generally worst near the fiducials which are most closely aligned! This should demonstrate the danger of relying on the traditional accuracy measure, namely fiducial registration error, to judge the quality of a registration.
منابع مشابه
The distribution of registration error of a fiducial marker in rigid-body point-based registration
Many image-guidance surgical systems rely on rigid-body, point-based registration of fiducial markers attached to the patient. Marker locations in image space and physical space are used to provide the transformation that maps a point from one space to the other. Target registration error (TRE) is known to depend on the fiducial localization error (FLE), and the fiducial registration error (FRE...
متن کاملبهبود سرعت "انطباق مبتنی بر روش برش گراف" جهت انطباق غیر صلب تصاویر تشدید مغناطیسی مغز
Image processing methods, which can visualize objects inside the human body, are of special interests. In clinical diagnosis using medical images, integration of useful data from separate images is often desired. The images have to be geometrically aligned for better observation. The procedure of mapping points from the reference image to corresponding points in the floating image is called Ima...
متن کاملFiducial point placement and the accuracy of point-based, rigid body registration.
OBJECTIVE To demonstrate that the shape of the configuration of fiducial points is an important factor governing target registration error (TRE) in point-based, rigid registration. METHODS We consider two clinical situations: cranial neurosurgery and pedicle screw placement. For cranial neurosurgery, we apply theoretical results concerning TRE prediction, which we have previously derived and ...
متن کاملA Novel Subsampling Method for 3D Multimodality Medical Image Registration Based on Mutual Information
Mutual information (MI) is a widely used similarity metric for multimodality image registration. However, it involves an extremely high computational time especially when it is applied to volume images. Moreover, its robustness is affected by existence of local maxima. The multi-resolution pyramid approaches have been proposed to speed up the registration process and increase the accuracy of th...
متن کاملGeometrical analysis of registration errors in point-based rigid-body registration using invariants
Point-based rigid registration is the method of choice for aligning medical datasets in diagnostic and image-guided surgery systems. The most clinically relevant localization error measure is the Target Registration Error (TRE), which is the distance between the image-defined target and the corresponding target defined on another image or on the physical anatomy after registration. The TRE dire...
متن کامل