The importance of the precorneal tear film for the quality of optical imaging.
نویسنده
چکیده
The optical function of the eye critically depends on the presence of an intact precorneal tear film. Abnormalities of the tear film such as those occurring in the dry eye syndrome or in otherwise irritated eyes may interfere with vision. In 30 patients with dry eyes artificial tears were found to produce statistically significant improvement of vision (p less than 0.001) while no significant changes were seen in the untreated partner eyes. Static perimetry in another 30 patients using the 'macular programme' of the automatic Humphrey 620 perimeter showed artificial tears to increase mean thresholds significantly (p less than 0.001) whereas no significant differences were seen in the untreated partner eyes.
منابع مشابه
Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography.
PURPOSE To demonstrate the feasibility of indirectly measuring the precorneal tear film thickness and pre- and postlens tear film (PLTF) thickness using optical coherence tomography (OCT). METHODS Central corneal thickness (C(1)) which includes the tear film (T) of both eyes of 40 non-contact lens wearers was measured using OCT after calibration. The mean age of the 40 subjects was 31.2 +/- 9...
متن کاملMeasuring of corneal thickness of contact lens wearers with keratoconus and keratoplasty by means of optical coherence tomography (OCT).
To measure the corneal thickness and the depth of the precorneal tear film of contact lens wearers with keratoconus or keratoplasty and to reconfirm the identification and classification of the keratoconus with optical coherence tomography (OCT). The cornea and precorneal tear film of 123 eyes with keratoconus, of 39 eyes after keratoplasty and 8 eyes after LASIK were examined with an OCT (Zeis...
متن کاملA new, specular reflection-based, precorneal tear film stability measurement technique in a rabbit model: viscoelastic increases tear film stability.
PURPOSE To develop a safe, noninvasive, noncontact, continuous in vivo method to measure the dehydration rate of the precorneal tear film and to compare the effectiveness of a viscoelastic agent in maintaining the precorneal tear film to that of a balanced salt solution. METHODS Software was designed to analyze the corneal reflection produced by the operating microscope's coaxial illumination...
متن کاملStudy of human precorneal tear film thickness and structure using laser interferometry.
The authors previously found that measurements of precorneal tear film thickness in animals, using laser interferometry and confocal microscopy, were larger than earlier estimates. They proposed that this occurred because optical methods did not disturb film structure and measured full thickness, including mucus. In the present study, tear film thickness was measured in humans. Coherent light w...
متن کاملA novel method for pachymetry mapping of human precorneal tear film using Pentacam with fluorescein.
PURPOSE To report a novel method for pachymetry mapping of human precorneal tear film using Pentacam. METHODS Precorneal tear film is routinely undetected by Pentacam but could be well visualized with the aid of fluorescein. Twenty patients with dry eye and 20 age-matched control subjects with normal eyes were enrolled in this prospective study. The right eye of each subject was scanned once ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 76 3 شماره
صفحات -
تاریخ انتشار 1992