Real-time correction of rigid body motion-induced phase errors for diffusion-weighted steady-state free precession imaging.

نویسندگان

  • Rafael O'Halloran
  • Murat Aksoy
  • Eric Aboussouan
  • Eric Peterson
  • Anh Van
  • Roland Bammer
چکیده

PURPOSE Diffusion contrast in diffusion-weighted steady-state free precession magnetic resonance imaging (MRI) is generated through the constructive addition of signal from many coherence pathways. Motion-induced phase causes destructive interference which results in loss of signal magnitude and diffusion contrast. In this work, a three-dimensional (3D) navigator-based real-time correction of the rigid body motion-induced phase errors is developed for diffusion-weighted steady-state free precession MRI. METHODS The efficacy of the real-time prospective correction method in preserving phase coherence of the steady state is tested in 3D phantom experiments and 3D scans of healthy human subjects. RESULTS In nearly all experiments, the signal magnitude in images obtained with proposed prospective correction was higher than the signal magnitude in images obtained with no correction. In the human subjects, the mean magnitude signal in the data was up to 30% higher with prospective motion correction than without. Prospective correction never resulted in a decrease in mean signal magnitude in either the data or in the images. CONCLUSIONS The proposed prospective motion correction method is shown to preserve the phase coherence of the steady state in diffusion-weighted steady-state free precession MRI, thus mitigating signal magnitude losses that would confound the desired diffusion contrast.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Steady-State Free Precession (SSFP) Diffusion Imaging Using 3D Rotating Spirals (3DRS)

INTRODUCTION 3D diffusion imaging has been an appealing but challenging topic over the last decade. It provides good properties such as isotropic resolution, higher SNR efficiency, and less inflow effect. However, it also suffers from long scan time and consequently more severe motion artifacts. Compared with traditional spinecho diffusion weighted imaging (DWI) method, steady-state free preces...

متن کامل

Nonlinear phase correction for navigated diffusion imaging.

Motion during diffusion-weighted imaging (DWI) introduces phase errors that can cause significant artifacts in brain images. One method of correcting these errors uses additional navigator data to measure the phase corruptions. Standard navigator methods correct for rigid-body motion but cannot correct for nonrigid deformations of the brain related to the cardiac cycle. This work derives a gene...

متن کامل

K-space and Image Space Combination for Motion-induced Phase Error Correction in 3D Diffusion-Weighted Imaging

INTRODUCTION In diffusion tensor imaging (DTI), high-resolution isotropic voxels are highly desirable to resolve small white matter structures. Isotropic voxels require high spatial resolution including the slice direction and can only be achieved with reasonable SNR with 3D diffusion-weighted imaging (DWI). A major problem with 3D DWI is motion-induced phase errors (MiP). Recently, 3D self-nav...

متن کامل

Combined Prospective Rigid-Body Motion Correction with Retrospective Non-Rigid Distortion Correction for EPI

Introduction: Prospective real-time motion correction, where the scan-plane orientation is dynamically updated to track with the subject's head during an MRI scan, is becoming increasingly popular (1-7). While these methods focus on compensating for bulk rigid-body motion, a secondary effect of head motion is non-rigid-body image distortion caused by changes in the effective shim within the bra...

متن کامل

Model for the correction of motion-induced phase errors in multishot diffusion-weighted-MRI of the head: are cardiac-motion-induced phase errors reproducible from beat-to-beat?

In diffusion-weighted imaging, multishot acquisitions are problematic due to intershot inconsistencies of the phase caused by motion during the diffusion-encoding gradients. A model for the motion-induced phase errors in diffusion-weighted-MRI of the brain is presented, in which rigid-body and nonrigid-body motion are separated. In the model, it is assumed that nonrigid-body motion is due to ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 73 2  شماره 

صفحات  -

تاریخ انتشار 2015