The Reversion Force of NiTi Orthodontic Wires in the Temperature

نویسنده

  • F. Fiorentini
چکیده

The interest in using the pseudoelastic properties of NiTi wires in orthodontic practice arises chiefly from the expectation that they can afford low continuous forces at constant temperature. The reversion force developed by NiTi archwires depends, however, upon temperature since the superelastic force follows a Clausius-Clapeyron like equation. Actually the oral environment temperature is modified as a consequence of hotJcold liquid/solid intake in the temperature range 5"5S°C, as previously evaluated. In the above-mentioned temperature range first results have already been obtained on the reversion force variation. Attention is focused here on the reversion force as a function of temperature under different fixed constraints. Tensile and 3-point bending tests have been performed on NiTi orthodontic wires, adopted in orthodontic practice, starting at body temperature: loading and partial unloading have been performed in order to fix different constraint conditions corresponding to different states in orthodontic therapy. The variation of the reversion force has been studied as a function of temperature. Evidence has been obtained of the hysteretic behaviour of the reversion force as a function of temperature. The results show that after a temperature loop to high temperature the reversion force is generally changed: the overall shape of the hysteresis cycle appears dominated by the presence of the R-phase at T<37OC and by the stress-induced martensite at P37OC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Reversion Force of NiTi Orthodontic Wires in the Temperature Domain 5 55 °C

The interest in using the pseudoelastic properties of NiTi wires in orthodontic practice arises chiefly from the expectation that they can afford low continuous forces at constant temperature. The reversion force developed by NiTi archwires depends, however, upon temperature since the superelastic force follows a Clausius-Clapeyron like equation. Actually the oral environment temperature is mod...

متن کامل

Pseudoelasticity of NiTi Orthodontic Wires Modified by Current Methodologies : A Critical Comparison

It is well known that applications of NiTi alloys in orthodontics rely on the pseudoelastic properties developed at temperatures hgher than Af. That implies as a necessary condtion that the body temperature (Tb) be higher than Af; the level of reversion stress, or depends moreover upon the difference between Tb and Af. Nowadays the interest is directed to obtain an archwire with distinct or in ...

متن کامل

Effects of Fluoride on NiTi Orthodontic Archwires: An X-ray Diffraction Study

Objective: To explore the changes in nickel-titanium (NiTi) archwires after exposure to fluoride-containing acetic acid solutions. Materials and methods: Preformed rectangular NiTi wires were immersed in either an acidulated fluoride solution, a neutral fluoride solution or distilled water (control) for 1.5 hours at 37°C. After immersion, the unloading force values at four deflection points wer...

متن کامل

Galvanic Corrosion of Orthodontic Brackets and Wires in Acidic Artificial Saliva: Part II

  Objective: Orthodontic wires should have high resistance against corrosion in the oral environment. Since the effect of pH on corrosion has been well recognized, this study sought to assess and compare the electrochemical corrosion of orthodontic brackets and wires of different brands in acidic artificial saliva.   Methods: This in vitro experimental study was conducted on 24 mandibular centr...

متن کامل

Galvanic Corrosion and Ion Release from Different Orthodontic Brackets and Wires in Acidic Artificial Saliva: Part I

&nbsp; Objective: Corrosion resistance is among the most important properties of metal alloys used in the oral cavity. Consumption of acidic foods reduces the salivary pH and intensifies the corrosion of brackets and orthodontic wires. This study aimed to compare electro galvanic corrosion of different orthodontic brackets and wires and determine the amount of ions released into acidic artifici...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007