Reproducibility of double indicator dilution measurements of intrathoracic blood volume compartments, extravascular lung water, and liver function.

نویسندگان

  • O Godje
  • M Peyerl
  • T Seebauer
  • O Dewald
  • B Reichart
چکیده

STUDY OBJECTIVE Arterial thermal dye dilution (TDDart) with the COLD system (Munich, Germany) allows measurement of cardiac index (CI), partial blood volumes, lung water, and liver function. The aim of the study was to determine agreement of TDDart measurements with pulmonary artery thermal dilution measurements (TDpa) and to assess the reproducibility of TDDart parameters. DESIGN Prospective study. SETTING ICU of a university hospital department of cardiac surgery. PATIENTS Thirty consecutive patients after coronary artery bypass grafting. MEASUREMENTS AND RESULTS Triplicate measurements of TDDart parameters were performed 1, 3, 6, 12, and 24 h postoperatively and coefficients of variation (CVs) were computed. At the 3-h point, additional fivefold TDDart measurements were done and compared with TDpa measurements. The coefficient of correlation for CI from TDDart vs TDpa was 0.96 (p<0.001), and the mean difference was 0.16 L/min/m2 (2.4%). The CVs of the TDDart and TDpa CI measurement were 7.2% and 5.9%; the CVs of other TDDart parameters were 4.6% (cardiac function index), 8.3% (global end-diastolic volume), 7.0% (intrathoracic blood volume), 7.6% (total blood volume), 7.4% (right ventricular end-diastolic volume), 7.4% (right heart end-diastolic volume), 11.3% (left heart end-diastolic volume [LHEDV]), 12.0% (right to left heart volume proportion [R/LHV]), 8.8% (pulmonary blood volume), 10.8% (extravascular lung water), 16.4% (plasma disappearance rate of dye), and 19.8% (dye clearance). The CV did not depend on Glasgow coma scale or on body temperature. CONCLUSION The CVs of LHEDV and R/LHV are influenced by asynchronous TDDart and TDpa variation. The CVs of plasma disappearance and dye clearance are increased as the half-life of the dye is longer than the measurement sequence. All other parameters derived from TDDart and TDpa show a clinically sufficient reproducibility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcardiopulmonary thermal dye versus single thermodilution methods for assessment of intrathoracic blood volume and extravascular lung water in major burn resuscitation.

The purpose of this study was to compare the approximated values for intrathoracic blood volume (ITBV) and extravascular lung water (EVLW) obtained from a single indicator dilution to the exact data measured by double-indicator dilution. Eighteen patients with an average TBSA of 46.3% (range, 26 to 67%) and an average abbreviated burn severity index of 8.7 (range, 7 to 11) were included into a ...

متن کامل

Thermal dye double indicator dilution measurement of lung water in man: comparison with gravimetric measurements.

The thermal dye double indicator dilution technique for estimating lung water was compared with gravimetric analyses in nine human subjects who were organ donors. As observed in animal studies, the thermal dye measurement of extravascular thermal volume (EVTV) consistently overestimated gravimetric extravascular lung water (EVLW), the mean (SEM) difference being 3.43 (0.59) ml/kg. In eight of t...

متن کامل

Effect of norepinephrine and fluid administration on pulmonary extravascular water volume in dogs.

The effects of norepinephrine-induced vasoconstriction on pulmonary extravascular water volume (PEWV) and central volume were studied before and after intravenous volume expansion with 5% dextrose and water (20 ml/kg body weight). PEWV was measured by double isotope dilution and gravimetric analysis and assessed by electron photomicrography. Comparisons were made with saline-treated control dog...

متن کامل

Inhaled nitric oxide does not prevent pulmonary edema after lung transplantation measured by lung water content: a randomized clinical study.

STUDY OBJECTIVE In order to assess the effects of inhaled nitric oxide (iNO) in preventing early-onset lung edema from occurring after lung transplantation, we measured extravascular lung water (EVLW) in a group of lung transplant recipients who were at high risk for developing ischemia-reperfusion-induced lung injury. DESIGN Prospective, randomized study. SETTINGS Surgical ICU in a teachin...

متن کامل

Preload index: pulmonary artery occlusion pressure versus intrathoracic blood volume monitoring during lung transplantation.

UNLABELLED In this study, during lung transplantation, we analyzed a conventional preload index, the pulmonary artery occlusion pressure (PAOP), and a new preload index, the intrathoracic blood volume index (ITBVI), derived from the single-indicator transpulmonary dilution technique (PiCCO System), with respect to stroke volume index (SVIpa). We also evaluated the relationships between changes ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 113 4  شماره 

صفحات  -

تاریخ انتشار 1998