Metabolic oxygen consumption measurement with a single-cell biosensor after particle microbeam irradiation.

نویسندگان

  • Yanping Xu
  • Bo Zhang
  • Mark Messerli
  • Gerhard Randers-Pehrson
  • Tom K Hei
  • David J Brenner
چکیده

A noninvasive, self-referencing biosensor/probe system has been integrated into the Columbia University Radiological Research Accelerator Facility Microbeam II end station. A single-cell oxygen consumption measurement has been conducted with this type of oxygen probe in 37° C Krebs-Ringer Bicarbonate buffer immediately before and after a single-cell microbeam irradiation. It is the first such measurement made for a microbeam irradiation, and a six fold increment of oxygen flux induced during a 15-s period of time has been observed following radiation exposure. The experimental procedure and the results are discussed.

منابع مشابه

Expanding the question-answering potential of single-cell microbeams at RARAF, USA.

Charged-particle microbeams, developed to provide targeted irradiation of individual cells, and then of sub-cellular components, and then of 3-D tissues and now organisms, have been instrumental in challenging and changing long accepted paradigms of radiation action. However the potential of these valuable tools can be enhanced by integrating additional components with the direct ability to mea...

متن کامل

Ion, X-ray, UV and Neutron Microbeam Systems for Cell Irradiation.

The array of microbeam cell-irradiation systems, available to users at the Radiological Research Accelerator Facility (RARAF), Center for Radiological Research, Columbia University, is expanding. The HVE 5MV Singletron particle accelerator at the facility provides particles to two focused ion microbeam lines: the sub-micron microbeam II and the permanent magnetic microbeam (PMM). Both the elect...

متن کامل

Research and development of focused proton microbeam irradiation system, SPICE for radio-biological studies.

There is continuing interest for the use of microbeam irradiation systems designed to deliver a defined number of charged particles on a single cell with a resolution of a few micrometers. Irradiation of an exact number of charged particles on a single cell means that the limitations of the Poisson distribution of the number of charged particles can be overcome. Moreover, microbeams are particu...

متن کامل

Future role of vitamin C in radiation mitigation and its possible applications in manned deep space missions: survival study and the measurement of cell viability

Background: Astronauts will be exposed to both chronic space radiation and acute high doses of energetic radiation of solar particle events in long-term deep space missions. The application of radioprotectors in space missions has basic limitations such as their very short time window as well as their acute toxicity and considerable side effects. The aim of the present study was to investigate ...

متن کامل

First Sub-Micron Targeting with Single Ions

Since 2003, we use the GSI heavy-ion microprobe to irradiate living cells with ions from the UNILAC [1]. Two specific properties of the microbeam method make it stand out among other, more conventional irradiation procedures: First, we precisely control the dose by counting and switching individual particles that are to be delivered to the target, down to the low-dose limit of a single ion per ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • Radiation and environmental biophysics

دوره 54 1  شماره 

صفحات  -

تاریخ انتشار 2015