Concentration of Formaldehyde, Acetaldehyde, and Five Volatile Organic Compounds in Indoor Air: The Clean-Healthy House Construction Standard (South Korea)
نویسندگان
چکیده
The authors evaluate indoor air quality in apartments built according to the South Korean Clean-Healthy House construction standard. The evaluation includes three types of residential units with differing gross floor areas. Indoor air was analyzed for formaldehyde (observed range 52.0–99.2 ug/m), acetaldehyde (14.6–61.0 ug/m), benzene (0.6–1.3 ug/m), toluene (161.8–371.0 ug/m) ethylbenzene (6.5–17.0 ug/m), xylene (14.7–45.0 ug/m), and styrene (37.7–112.5 ug/m). The concentrations of all analyzed substances were within the South Korean guidelines. The findings confirm that the Clean-Healthy Homes initiative has led to a greatly improved indoor air environment compared to existing newly built apartment blocks in South Korea. However, this construction standard is applied only to large apartment developments comprising 1,000 or more units, and it seems that further effort should be made to extend the standard to stand-alone residences and small-scale apartment blocks in order to ensure that indoor air quality is maintained more widely.
منابع مشابه
Assessment of VOCs, PM10, and Formaldehyde Exposure in the Hair Salons of South Korea
Introduction: In hair salons, workers and customers are exposed to high concentrations of several chemical compounds used during the working environment. Volatile Organic Compounds (VOCs), particulate matter (PM10), nitrogen dioxide (NO2), sulfur dioxide (SO2), carbon monoxide (CO), and formaldehyde are the major chemicals that alter the indoor air quality. This study aimed to assess the indoor...
متن کاملAsthmatic symptoms and volatile organic compounds, formaldehyde, and carbon dioxide in dwellings.
OBJECTIVES As a part of the worldwide European Community respiratory health survey, possible relations between symptoms of asthma, building characteristics, and indoor concentration of volatile organic compounds (VOCs) in dwellings were studied. METHODS The study comprised 88 subjects, aged 20-45 years, from the general population in Uppsala, a mid-Swedish urban community, selected by stratif...
متن کاملEffectiveness of Portable Room Air Cleaners for Control of Volatile Organic Compounds in Indoor Air
IAQ T1S3) Eleven commercially available portable room air cleaners have been tested on a mixture of 16 representative volatile organic compounds (VOC) in a full-scale stainless steel chamber and their initial VOC removal efficiencies have been evaluated. These products use different gas-phase contaminant removal technologies including adsorption, photocatalytic oxidation under UV irradiation (U...
متن کاملFormaldehyde and volatile organic compounds in Hong Kong homes: concentrations and impact factors.
UNLABELLED This paper presents formaldehyde and volatile organic compounds (VOC) concentrations, potential sources and impact factors in 100 homes. The 24-h average formaldehyde concentration in 37 homes exceeded the good class of the Hong Kong Indoor Air Quality Objectives (HKIAQO), whereas the total VOCs concentration in all homes was lower than the HKIAQO. Compared to other East Asian cities...
متن کاملStudy of the removal difference in indoor particulate matter and volatile organic compounds through the application of plants
This study was conducted to evaluate the ability of plants to purify indoor air by observing the effective reduction rate among pollutant types of particulate matter (PM) and volatile organic compounds (VOCs). PM and four types of VOCs were measured in a new building that is less than three years old and under three different conditions: before applying the plant, after applying the plant, and ...
متن کامل