Chest wall thickness measurements of the LLNL phantom for small area germanium detector counting.

نویسندگان

  • G H Kramer
  • T Y Lee
  • S Y Chang
چکیده

The Lawrence Livermore National Laboratory (LLNL) phantom was developed to calibrate lung counting systems that are used to estimate plutonium and other low energy photon emitting radionuclides deposited in the lung. Originally, low energy photon counting systems consisted of sodium iodide or phoswich detectors, but they have been largely replaced by smaller germanium detector arrays. The average chest wall thicknesses of the LLNL phantom's torso plate and its overlay plates provided by the manufacturer refer to the regions covered by phoswich detectors; however, germanium detectors are of a different size and are placed in different locations on the phantom's torso plate. Previous work has shown that the manufacturer's data were not applicable for large area germanium detectors. The lung counting system at the Korea Atomic Energy Institute (KAERI) is a small area germanium detector array. Although the detectors are placed within the phoswich circles, only about 25% of the area is covered by the detectors. The LLNL phantom at KAERI has been examined to determine if the manufacturer's data are valid or if new chest wall thickness values must be determined. This paper presents chest wall thickness data for the LLNL phantom with and without its B-series overlay plates at 17 keV, 60 keV, 200 keV, and 1,500 keV and shows that these values are different from the manufacturer's values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lung counting: a function to fit counting efficiency of a lung counting germanium detector array to muscle-equivalent-chest-wall-thickness and photon energy using a realistic torso phantom.

A function has been developed that will fit counting efficiency to chest wall thickness, adipose content of the chest wall, and photon energy. The adipose content of the chest wall is removed as a variable by use of the derived quantity: muscle equivalent chest wall thickness. The function has been tested on experimental data sets obtained from the LLNL and JAERI torso phantoms using a variety ...

متن کامل

Chest wall thickness measurements and the dosimetric implications for male workers in the uranium industry.

The Human Monitoring Laboratory has measured the chest wall thickness and adipose mass fraction of a group of workers at a Canadian uranium refinery, a conversion plant, and a fuel fabrication site using ultrasound. A site-specific biometric equation has been developed for these workers, who seem to be somewhat larger than other workers reported in the literature. Chest wall thickness is a very...

متن کامل

An improved Virtual Torso phantom

INTRODUCTION Lung counting has many sources of uncertainty that can impact on the activity estimate such as different deposition patterns of radioactivity in the lung, rib size and placement, chest wall composition and profile, effect of detector size and thickness. For example, if a lung counter is calibrated using a lung set that has the activity homogeneously distributed throughout the tissu...

متن کامل

MCNP evaluation of the effect of chest wall thickness, tissue composition, and photon energy on the quantity Muscle-Equivalent-Chest-Wall-Thickness

The measurement of radioactivity deposited in the lung is often performed with an array of germanium detectors placed over the chest of the individual. The detector array size can be from four to eight detectors depending on the size of the germanium detector and Dewar assembly. Typically, large area diameter germanium detectors (70 mm diameter) consist of four detectors, and the larger arrays ...

متن کامل

NIST Virtual Gamma Spectrometry System: A Comparison of Counting Efficiencies from Measurements and Monte Carlo Simulations

Anthropometric and anthropomorphic phantoms have been used extensively for characterizing in-vivo measurement systems that determines internally deposited radionuclides. The accuracy in activity determination relies critically on system design, calibration routine, and reproducbility in material composition, geometry configuration, and physical dimensions of the phantoms respect to the actual o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Health physics

دوره 79 2  شماره 

صفحات  -

تاریخ انتشار 2000