Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients
نویسندگان
چکیده
Differences in dialyzer design may have consequences for patient outcomes. We evaluated the comparative effectiveness of commonly used dialyzers with respect to measures of dialysis treatment, anemia management, inflammation, and dialyzer clotting. Patients receiving hemodialysis between January 1, 2009, and December 31, 2013, and using polyarylethersulfone-polyvinylpyrrolidone (PAS-PVP; Polyflux Revaclear) or polysulfone (PS; Optiflux 160 or Optiflux 180) dialyzers were followed for 1 year or until end of study or censoring for dialyzer switch, modality change, or loss to follow-up. For each comparison, eligible patients were propensity score-matched 1:1 on a range of baseline characteristics. Outcomes were assessed using generalized linear mixed models. Dialysis adequacy was similar in both dialyzer groups. Erythropoiesis-stimulating agent (ESA) doses were lower for patients using PAS-PVP versus patients using PS-160 (difference range: 75-589 units/treatment; statistically significant in months 1-5 and 7) and for patients using PAS-PVP versus patients using PS-180 (difference range: 27-591 unit/treatment; statistically significant in months 1-9). Intravenous iron doses trended lower for patients using PAS-PVP versus patients using PS, but hemoglobin concentrations were equivalent. In conclusion, use of PAS-PVP versus PS dialyzers was associated with equivalent dialysis adequacy, lower ESA doses, modestly lower Intravenous iron doses, and equivalent hemoglobin concentrations.
منابع مشابه
Comparative effectiveness of home dialysis therapies: a matched cohort study
BACKGROUND Home dialysis is being increasingly promoted among patients with end-stage renal disease, but the comparative effectiveness of home hemodialysis and peritoneal dialysis is unknown. OBJECTIVE To determine whether patients receiving home daily hemodialysis have reduced mortality risk compared with matched patients receiving home peritoneal dialysis. DESIGN This study is an observat...
متن کاملCost-effectiveness of hemodialysis and peritoneal dialysis: A national cohort study with 14 years follow-up and matched for comorbidities and propensity score
Although treatment for the dialysis population is resource intensive, a cost-effectiveness analysis comparing hemodialysis (HD) and peritoneal dialysis (PD) by matched pairs is still lacking. After matching for clinical characteristics and propensity scores, we identified 4,285 pairs of incident HD and PD patients from a Taiwanese national cohort during 1998-2010. Survival and healthcare expend...
متن کاملComparative effectiveness of calcium-containing phosphate binders in incident U.S. dialysis patients.
BACKGROUND AND OBJECTIVES Few studies have assessed the association between phosphate binder use and hard outcomes in dialysis patients. Furthermore, the comparative effectiveness of calcium carbonate and acetate is untested. We studied the association between use versus nonuse of calcium-containing phosphate binders (CCPBs) and mortality from any cause. We also tested whether mortality differe...
متن کاملAn Incident Cohort Study Comparing Survival on Home Hemodialysis and Peritoneal Dialysis (Australia and New Zealand Dialysis and Transplantation Registry).
BACKGROUND AND OBJECTIVES Home dialysis is often recognized as a first-choice therapy for patients initiating dialysis. However, studies comparing clinical outcomes between peritoneal dialysis and home hemodialysis have been very limited. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS This Australia and New Zealand Dialysis and Transplantation Registry study assessed all Australian and New Zea...
متن کاملDialyzer reuse with peracetic acid does not impact patient mortality.
BACKGROUND AND OBJECTIVES Numerous studies have shown the overall benefits of dialysis filter reuse, including superior biocompatibility and decreased nonbiodegradable medical waste generation, without increased risk of mortality. A recent study reported that dialyzer reprocessing was associated with decreased patient survival; however, it did not control for sources of potential confounding. W...
متن کامل