Reduction of NaTech Risk Due to Lightning by the Use of Protection Systems

نویسندگان

  • Amos Necci
  • Giacomo Antonioni
  • Valerio Cozzani
  • Alberto Borghetti
  • Carlo Alberto Nucci
چکیده

Several accidents that occurred in the last decades evidenced that the impact of natural events in industrial plants may trigger accidental scenarios involving the release of relevant quantities of hazardous substances. Severe scenarios typical of the process industry, as fires, explosions, toxic releases, and water pollution were reported as the consequence of natural events in industrial areas. The specific features of technological accidents triggered by natural events were recently recognized, and these scenarios are now indicated as NaTech (natural-technological) accidents. The screening of past accident databases points out that NaTech scenarios are quite common in industrial facilities. Past accident analysis evidences that lightning is one of the most common initiator event for fires in oil refineries and tank farms. In most facilities, simple lightning protection measures, such as grounding or lighting rods, are implemented to reduce the risk due to lightning strikes. However, several accidents suggest that these measures may not be sufficient to retain the structural integrity of the equipment. In the present study a procedure for the determination of the mitigation effect due to lightning rods on storage tank farms is proposed. A statistical method was developed to evaluate the failure frequency of tanks due to lightning strikes. The model includes both the assessment of lightning impact probability and of tank damage conditional probability given the lightning impact. The method then considers the effect of lightning rods placed at given distances from the equipment items and calculates the reduction of the failure frequency due to attraction competition between the rods and the equipment. The procedure was implemented in a GIS-based software tool for the calculation of individual and societal risk. The method allows the assessment of the effect of lightning protection in terms of individual risk reduction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مکان یابی برقگیر در مزرعه بادی به کمک الگوریتم ژنتیک

Due to the ever-increasing use of Distributed Generations (DGs), and special attentions toward wind power plants in recent years, this research investigates the wind plants from the viewpoint of lightning protection. In comparison to all other type of generators connected to the electric power systems, wind turbine generators are placed in areas which are more likely to be stricken by lightning...

متن کامل

Industrial accidents triggered by natural hazards: an emerging risk issue

The threat of natural hazards impacting chemical facilities and infrastructures with the subsequent release of hazardous substances has been recognised as an emerging risk which is likely to be exacerbated by the ongoing climate change. Within the European FP7 project iNTeg-Risk, efforts are dedicated to address the problem of Natech accidents by trying to understand their underlying causes and...

متن کامل

Sensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation

 Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...

متن کامل

Breast Radiation Protection in Coronary Angiography

Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In ord...

متن کامل

Lightning Protection of Ehv Substations in Iran

Extra high voltage (EHV) substations are extremely vulnerable to the hazard of lightning strokes therefore, the shielding of these substations with a highly reliable protective scheme (shield wires) is an essential undertaking. In this paper an attempt is made to clarify the design procedure for shielding EHV substations against lightning with special reference to Iran.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013