The impact of beat-to-beat variability in optimising the acute hemodynamic response in cardiac resynchronisation therapy
نویسندگان
چکیده
BACKGROUND Acute indicators of response to cardiac resynchronisation therapy (CRT) are critical for developing lead optimisation algorithms and evaluating novel multi-polar, multi-lead and endocardial pacing protocols. Accounting for beat-to-beat variability in measures of acute haemodynamic response (AHR) may help clinicians understand the link between acute measurements of cardiac function and long term clinical outcome. METHODS AND RESULTS A retrospective study of invasive pressure tracings from 38 patients receiving an acute pacing and electrophysiological study was performed. 602 pacing protocols for left ventricle (LV) (n = 38), atria-ventricle (AV) (n = 9), ventricle-ventricle (VV) (n = 12) and endocardial (ENDO) (n = 8) optimisation were performed. AHR was measured as the maximal rate of LV pressure development (dP/dtMx) for each beat. The range of the 95% confidence interval (CI) of mean AHR was ~ 7% across all optimisation protocols compared with the reported CRT response cut off value of 10%. A single clear optimal protocol was identifiable in 61%, 22%, 25% and 50% for LV, AV, VV and ENDO optimisation cases, respectively. A level of service (LOS) optimisation that aimed to maximise the expected AHR 5th percentile, minimising variability and maximising AHR, led to distinct optimal protocols from conventional mean AHR optimisation in 34%, 78%, 67% and 12.5% of LV, AV, VV and ENDO optimisation cases, respectively. CONCLUSION The beat-to-beat variation in AHR is significant in the context of CRT cut off values. A LOS optimisation offers a novel index to identify the optimal pacing site that accounts for both the mean and variation of the baseline measurement and pacing protocol.
منابع مشابه
Studies on thiopentone and midazolam hemodynamic response during induction of anesthesia in patients with coronary artery disease
Background: Induction of anesthesia in patients that undergo cardiac surgery has more risk than others, because of specific cardiovascular effects of the anesthetic drugs and the preoperative state of these patients, so the hemodynamic stability is very important in these patients. It seems that midazolam have less cardiovascular side effects than thiopentone. In this study, the effects of mid...
متن کاملEffect of endotoxemia on heart rate dynamics in rat isolated perfused hearts
Introduction: Beat-to-beat variation in heart rate shows a complex dynamics, and this complexity is changed during systemic inflammatory response syndrome (e.g. sepsis). It is not known whether or not cardiac pacemaker dynamical rhythm is affected by sepsis. The aim of this study was to investigate heart rate dynamics of isolated heart as well as expression of pacemaker channels (HCN) in a r...
متن کاملارتباط الگوی ضربان قلب جنین با تعداد گلبولهای قرمز هستهدار در خون بند ناف هنگام تولد
Background: Previous studies have suggested the presence of a relationship between the increase of NRBC and the duration and intensity of asphyxia. The purpose of this study was to evaluate the relationship of fetal heart rate pattern and the number of NRBC's in umbilical cord blood sample at birth. Methods: We enrolled 322 pregnant women with healthy, term fetuses who referred to Mirza Koucha...
متن کاملEffects of Lidocaine on the Acute Hemodynamic Response to Electroconvulsive Therapy
ABSTRACT Electroconvulsive therapy (ECT) has been used widely to treat psychiatric disease. ECT under anesthesia is associated with hypertension and tachycardia. The cardiovascular effects of ECT were studied after per-treatment of 100 patients with lidocaine 1.5 mg/Kg (experimental group) and saline solution (control), using a double-blind, randomized clinical trial study. There were no sign...
متن کاملContinuous Hemodynamic Monitoring in Acute Stroke: An Exploratory Analysis
INTRODUCTION Non-invasive, continuous hemodynamic monitoring is entering the clinical arena. The primary objective of this study was to test the feasibility of such monitoring in a pilot sample of Emergency Department (ED) stroke patients. Secondary objectives included analysis of hemodynamic variability and correlation of continuous blood pressure measurements with standard measurements. MET...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2015